.002
.005
((No OF POS x .050) + .015)
REVISION K
FIG. 1
ISDF-XX-D-X
SEE NOTE 2
C1
ISDF-10-D-X SHOWN
NOTCH SPECIFICATION
(No OF POS x .050) - .050
(TOL NON-ACCUM)
No OF POSITIONS
R.001
LEAVE BLANK: NO NOTCH
-C: CHAMFER (SEE SHEET 2,
FIG 2) (7 POSITION ONLY)
-L: FRICTION LOCK
-02 THRU -50
(PER ROW)
K
.025 (TYP)
C
L
"A"
.020 (TYP)
(SEE SHEET 2, FIG 3)
DO NOT
SCALE FROM
THIS PRINT
(AVAILABLE ON POS 10 - 30)
-R: RETENTION LATCH (AVAILABLE
ON POS -05 THRU -30)
(SEE SHEET 3, FIG 4)
.250
.180
C
L
.1200
.1450
(SEE NOTE 11)
ROW SPECIFICATION
-D: DOUBLE ROW
A
"A"
SEE NOTE 3
.033
.003
.0800±.0020
.050
C5
.030
"B"
.030
SEE NOTE 4
'C'
.0500
C
L
.050
.058
C4
.415
.440
.4260
.103
R.005 TYP
.077
.003
R.001
C2
.0420
"B"
'E'
.0260
C3
.0525
.0430
C8
SECTION "A"-"A"
.2180
SEE NOTE 7
.0150 REF
C7
C6
SEE NOTE 8
'D'
"F"
.0410
02 04 06 08 10 12 14 16 18 20
SECTION "B"-"B"
C
L
.070
01
05 07 09 11
15 17 19
13
03
NOTES:
"F"
C
1.
REPRESENTS A CRITICAL DIMENSION.
SECTION "F"-"F"
2. SAMTEC LOGOS SHALL APPEAR AT LOCATIONS ON SURFACE SHOWN,
APPROXIMATELY .075 x .055 (BOTH SIDES).
3. ALL MULTIPLE CAVITY MOLDS SHALL IDENTIFY EACH CAVITY WITH A LETTER
DESIGNATION LOCATED WHERE SHOWN.
4. IDENTIFICATION MARKS NOT TO PROTRUDE BEYOND .001 ABOVE THE SURFACE
OF THE INSULATOR MATERIAL.
5. MOLDED SURFACES SHALL BE CONSISTENT AND SMOOTH. SURFACES TO BE
FREE OF SCATCHES, NICKS, SINK AREAS, VOIDS OR OTHER BLEMISHES.
6. PART TO BE SYMMETRIC ABOUT THE CENTERLINE WITHIN +/-.0015, UNLESS
OTHERWISE STATED.
7. GATE PADS MUST BE RECESSED .005.
8. SPECIFIED POSITIONS TO BE IDENTIFIED WHERE SHOWN (NOTE 4 APPLIES).
9. R.005 OPTIONAL.
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
2
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail: info@SAMTEC.com code: 55322
.XXX: .003 [.08]
.XXXX: .0015 [.038]
SHEET SCALE: 4:1
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
VECTRA S475, COLOR: BLACK
MAX REGRIND: 50%
.050" CL CRIMP WIRE SOCKET INSULATOR
DWG. NO.
10. POSITIONS -10 THROUGH -24 WILL HAVE ONLY ONE LATCH LOCK AT DIMENSION SHOWN;
POSITIONS -25 THROUGH -30 WILL HAVE TWO LATCH LOCKS AT DIMENSION SHOWN.
11. OPTION NOT FOR SALE. FOR RETENTION LATCH FEATURE, SEE ISDF-XX-D-M PRINT.
ISDF-XX-D-X
BRATCHER 5/4/2005
MAX FLASH ALLOWED: .002
MAX GATE VESTIGE: .004
SHEET 1 OF 3
BY:
F:\DWG\MISC\MKTG\ISDF-XX-D-X-MKT.SLDDRW