IRS2181/IRS21814(S)PbF
Dynamic Electrical Characteristics
V
(V , V ) = 15 V, V = COM, C = 1000 pF, T = 25 °C.
BIAS CC BS
L
A
SS
Symbol
Definition
Min. Typ. Max. Units Test Conditions
t
Turn-on propagation delay
Turn-off propagation delay
Delay matching, HS & LS turn-on/off
Turn-on rise time
—
—
—
—
—
180
220
0
270
330
35
V = 0 V
S
on
t
V = 0 V or 600 V
S
off
MT
ns
t
40
20
60
r
V
S
= 0 V
t
f
Turn-off fall time
35
Static Electrical Characteristics
V
(V , V ) = 15 V, V = COM and T = 25 °C unless otherwise specified. The V , V and I parameters are
BIAS CC BS
SS
A
IL IH,
IN
referenced to V /COM and are applicable to the respective input leads HIN and LIN. The V , I and R parameters
SS
O O,
on
are referenced to COM and are applicable to the respective output leads: HO and LO.
Symbol
Definition
Min. Typ. Max. Units Test Conditions
2.5
V
Logic “1” input voltage
—
—
—
IH
VCC = 10 V to 20 V
0.8
1.4
0.2
50
V
Logic “0” input voltage
—
—
—
—
20
50
IL
V
µA
V
V
OH
High level output voltage, V
- V
O
—
I
= 0 A
BIAS
O
V
OL
Low level output voltage, V
—
I = 20 mA
O
O
I
LK
Offset supply leakage current
—
V
= V = 600 V
B S
I
Quiescent V supply current
BS
60
120
150
240
QBS
V
= 0 V or 5 V
IN
I
Quiescent V
supply current
CC
QCC
I
Logic “1” input bias current
Logic “0” input bias current
VIN = 5 V
VIN = 0 V
—
—
25
—
60
IN+
I
5.0
IN-
V
V
and V supply undervoltage positive going
CC BS
CCUV+
8.0
7.4
0.3
8.9
8.2
0.7
9.8
9.0
—
V
threshold
V and V supply undervoltage negative going
CC
BSUV+
V
CCUV-
BS
V
threshold
BSUV-
V
CCUVH
Hysteresis
V
BSUVH
V
O
= 0 V,
IO+
IO-
Output high short circuit pulsed current
Output low short circuit pulsed current
1.4
1.8
1.9
2.3
—
—
PW ≤ 10 µs
= 15 V,
O
A
V
PW ≤ 10 µs
www.irf.com
3