ICS93V857
Preliminary Product Preview
Recommended Operating Condition (see note1)
TA = 0 - 85C; Supply Voltage AVDD, VDD = 2.5 V +/- 0.2V (unless otherwise stated)
SYMBOL
MIN
2.3
TYP
MAX
2.7
VDDQ/2 -0.18
0.7
UNITS
PARAMETER
Supply Voltage
CONDITIONS
VDDQ, AVDD
V
V
V
V
V
CLKT, CLKC, FBINC
VIL
VIH
Low level input voltage
High level input voltage
PD#
-0.3
DDQ/2 +018
V
CLKT, CLKC, FBINC
PD#
V
DDQ +0.6
VDDQ
1.7
DC input signal voltage
(note 2)
-0.3
V
VDDQ +0.6
DDQ +0.6
Differential input signal
voltage (note 3)
DC - CLKT, FBINT
AC - CLKT, FBINT
0.36
0.7
V
V
VID
V
Output differential cross-
voltage (note 4)
Input differential cross-
VOX
VIX
VDDQ/2 -0.2
VDDQ/2 -0.2
VDDQ/2 +0.2
VDDQ/2 +0.2
V
V
voltage (note 4)
IOH
IOL
SR
High level output current
-12
12
4
mA
mA
Low level output current
Input slew rate
Operating free-air
temperature
1
0
V/ns
TA
85
°C
Notes:
1. Unused inputs must be held high or low to prevent them from floating.
2. DC input signal voltage specifies the allowable DC execution of differential input.
3. Differential inputs signal voltages specifies the differential voltage [VTR-VCP] required for
switching, where VT is the true input level and VCP is the complementary input level.
4. Differential cross-point voltage is expected to track variations of VCC and is the voltage at
which the differential signal must be crossing.
4