Current Transducers, HY 50-P/SP1
IPN = 50 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
Primary nominal
r.m.s. current
Primary current
measuring range
IP (A)
Primary
conductor
(mm)
Type
I
PN (A)
Features
50
± 150
1.6 x 3.5
HY 50-P/SP1
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500 V~
• Compact design for PCB mounting
• Low power consumption
• Extended measuring range (3 x IPN)
• Insulated plastic case recognized
according to UL 94-V0.
VC
IC
Supply voltage (± 5 %)
Current consumption
single + 5
V DC
10
mA
Î P
Overload capability (1 ms)
50 x IPN
Vd
Vb
R.m.s. voltage for AC isolation test, 50/60Hz, 1 min 2.5
kV
V
R.m.s. rated voltage,safe separation
Isolation resistance @ 500 VDC
Output voltage @ + IPN, RL = 10 kΩ, TA = 25°C
Output voltage @ - IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
5001)
R IS
VOUT
> 1000
2.5
MΩ
V
1.5
V
Ω
ROUT
RL
100
> 1
Advantages
Load resistance
kΩ
• Easy mounting
Accuracy - Dynamic performance data
• Small size and space savings
• Only one design for wide current
ratings range
• High immunity against external
interference
X
Accuracy @ IPN, TA = 25°C (without offset)
Linearity 2) (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0
after an excursion of 1 x IPN
Thermal drift of VOE
< ± 2
< ± 1 % of IPN
< + 2V ± 25 mV
%
ε
VOLE
VOH
< ± 10
± 1.5
± 3
< ± 0.1
< 5
mV
mV/K
mV/K
%/K
µs
VOT
typ
max
Applications
TCε
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
di/dt accurately followed
Frequency bandwidth 3) (0 .. - 3 dB)
G
• General purpose inverters
• Switched-Mode Power Supplies
(SMPS)
• AC motor speed control
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
tr
di/dt
f
> 50
DC .. 50
A/µs
kHz
General data
TA
TS
m
Ambient operating temperature
- 10 .. + 80 °C
- 25 .. + 85 °C
< 14
• Power supplies for welding
applications.
Ambient storage temperature
Mass
g
4)
Standards
EN50178
Notes : 1) Pollution class 2, overvoltage category III
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
4) Please consult characterisation report for more techinical details and
application advises.
980723/2