Current Transducer HX 03 .. 50-P
IPN = 3 .. 50 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primarynominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
Primary Conductor
Diameter x Turns
(mm)
Type
Features
3
5
± 9
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
HX 03-P
HX 05-P
HX 10-P
HX15-P
HX20-P
HX25-P
HX50-P
· Galvanicisolationbetweenprimary
andsecondarycircuit
· Halleffectmeasuringprinciple
· Isolationvoltage 3000V
± 15
± 30
± 45
± 60
± 75
± 150
10
15
20
25
50
· Low power consumption
1.2 x 6.3 x 1T
· Extendedmeasuringrange(3xIPN
· Power supply from ±12V to ±15V
· MaterialaccordingtoUL94-V0
)
VOUT
ROUT
R L
VC
Output voltage @ ± IPN, RL = 10 kW, TA = 25°C
Outputimpedance
Loadresistance
Supply voltage (± 5 %)1)
Currentconsumption
± 4
< 50
³ 10
± 15
< ± 15
V
W
kW
V
mA
kV
Advantages
I C
Vd
Ve
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn > 3
R.m.s. voltage for partial discharge extinction
· Low insertion losses
· Easy to mount with automatic
handlingsystem
at10pC
³ 1
³ 6
kV
kV
Impulse withstand voltage, 1.2/50µs
· Small size and space saving
· Only one design for wide current
ratingsrange
Accuracy-Dynamic performance data
· Highimmunitytoexternal
interference.
X
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
< ± 1
< ± 1
< ± 40
% of IPN
% of IPN
mV
e
VOLE
VOH
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (-3 dB) 2)
< ± 15
max. ± 1.5
± 0.1
mV
mV/K
%/K
µs
Applications
VOT
TCe
tr
· SwitchedModePowerSupplies
(SMPS)
· ACvariablespeeddrives
· UninterruptiblePowerSupplies
(UPS)
G
£ 3
50
f
kHz
General data
· Electricalappliances
· Batterysuppliedapplications
· DC motor drives
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
Min. internal creepage distance/clearance
Isolation material group
Standards
³ 5.5
I
EN50178
mm
Notes :1) Also operate at ±12V power supplies, measuring range reduced to ±2.5xIPN
2) Small signal only to avoid excessive heating of the magnetic cores
030806/5
www.lem.com