5秒后页面跳转
HWS30-12 PDF预览

HWS30-12

更新时间: 2024-11-24 14:58:55
品牌 Logo 应用领域
东电化 - TDK /
页数 文件大小 规格书
2页 369K
描述

HWS30-12 数据手册

 浏览型号HWS30-12的Datasheet PDF文件第2页 
HWS50-1500/HD Series  
Single Output Industrial Power Supplies  
Features  
u Limited Lifetime Warranty  
u -10 to +71°C Operation (-40°C start up)  
u Universal Input (85 - 265VAC)  
u Conformally coated pcbs  
u Class 1 Div 2 option (/RYHD suffix)  
u Wide range AC Input  
Key Market Segments & Applications  
Specifications  
Model  
HWS50  
HWS100  
HWS150  
HWS300  
HWS600  
HWS1000 HWS1500  
Input Voltage range (47-63Hz)  
-
A
A
-
-
-
V
ms  
mA  
-
85-265VAC or 120-370VDC  
85-265VAC or 120-330VDC (No DC input for HWS1500)  
Input Current (Typ)  
Inrush Current  
(1)  
(1)  
0.7 / 0.35  
1.3 / 0.65  
14 / 2  
1.9 / 0.95  
4.1 / 2.1  
8.1 / 3.9  
13.5 / 7  
19 / 10  
20 / 4  
Power Factor  
Meets EN61000-3-2  
<0.02%/°C  
Temperature Coefficient  
Overcurrent Protection  
Overvoltage Protection  
Hold Up Time (Typ)  
Leakage Current (60Hz)  
Remote Sense  
>104%  
Yes (See table on page 2)  
20  
<0.75mA  
Yes  
<0.5mA  
<1.2mA  
≤1.5mA  
No  
Indicator  
-
Green LED = ON  
Remote On/Off  
Parallel operation  
DC Good  
-
-
-
No  
No  
No  
Yes (Isolated from output)  
Single wire connection (5 units max)  
Yes  
Remote Adjust (PV)  
Operating Temperature  
and Derating (operation to  
+74°C - contact factory)  
Storage Temperature  
Humidity (non condensing)  
Cooling  
-
°C  
No  
Yes (3)  
HWS50-150: -10°C to +71°C, (-10 ~+50°C: 100%, +60°C: 60%, +71°C: 20%)  
HWS300-1500: -10°C to +71°C, (-10 ~+50°C: 100%, derate linearly to 50% load from +50 to +71°C)  
Guaranteed start up at -40°C (see specification sheets on website for details and derating)  
-40 to +85°C  
°C  
-
-
Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH  
Convection  
Internal fan  
Withstand Voltage  
Isolation Resistance  
Vibration (non operating)  
Shock (in packaging)  
Safety Agency Approvals  
Line Dip  
(2)  
-
-
-
-
-
-
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.  
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC  
MIL-STD-810F 514.5 Category 4, 10 (HWS1500 Cat 4, figure 514.5C-1)  
MIL-STD-810F 516.5 Category I, VI (HWS1500 <196.1m/s2)  
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark  
Complies with SEMI F47 (200VAC line only)  
Conducted & Radiated EMI  
Immunity  
-
-
EN55011 / EN55022-B, FCC-B, VCCI-B (HWS1500 Class A)  
IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5, -8 (Level 4), -11  
Weight (Typ)  
Size (WxHxD)  
Warranty  
g
in  
yrs  
280  
450  
500  
1000  
1600  
3200  
3800  
5x3.25x11  
1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 5x3.2x9.5  
Limited lifetime warranty (See TDK-Lambda’s terms & conditions)  
(1) 100/200VAC input  
(3) 1-6V program voltage input to adjust output 20-120% (typical) of  
(2) HWS300-600 2.5kVAC Input to ground  
nominal. See instruction manual for details & models with this feature.  
(*) Class 1 Div 2 option (/RYHD suffix  
1-800-526-2324 • www.us.tdk-lambda.com/lp/  