HO 60 .. 250-P series
Insulation coordination
Parameter
Symbol
Unit
Value
Comment
Rms voltage for AC insulation test 50/60 Hz/1 min
Ud
kV
4.3
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction rms voltage @ 10 pC
Clearance (pri. - sec.)
ÛW
Ue
kV
V
8
> 1170
> 8
Busbar / Secondary + jumpers
Shortest distance through air
Shortest path along device body
dCI
dCp
mm
mm
Creepage distance (pri. - sec.)
> 8
When mounted on PCB with
recommended layout
Clearance (pri. - sec.)
-
mm
> 8
V0 according to
Case material
-
-
UL 94
Comparative tracking index
CTI
600
Reinforced insulation, non
uniform field according to
EN 50178, EN 61010
600 V
CAT III PD2
Application example
Application example
Application example
-
-
-
-
-
-
Based insulation, non uniform
field according to
EN 50178, EN 61010
1000 V
CAT III PD2
600 V
CAT III PD2
Simple insulation, non uniform
field according to UL 508
Environmental and mechanical characteristics
Parameter
Symbol
Unit
°C
Min
−40
−40
Typ
Max
105
Comment
Ambient operating temperature
TA
TS
m
Ambient storage temperature
°C
105
Mass
g
34
Page 3/15
16July2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com