High Speed, Multi-point Laser Displacement Sensor
1063
HL-D3 SERIES
Glossary of terms / General precautions ..... P.1587 / P.1595
■General terms and conditions............. F-3
■
■Selection guide........................... P.1021~
■About laser beam........................ P.1593~
FIBER
SENSORS
Related Information
LASER
SENSORS
■Korea’s KC-mark ......................... P.1602
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Conforming to
FDA regulations
(HL-D301B/D301C
Ver.2
)
only
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
This product is classified
as a Class 2 / Class 3R
Laser Product in IEC /
JIS standards and FDA*
regulations. Do not look
at the laser beam directly
or through optical devices
such as a lens.
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
* This product complies with 21 CFR 1040.10
and 1040.11 Laser Notice No. 50, dated
June 24, 2007, issued by CDRH (Center for
Devices and Radiological Health) under the
FDA (Food and Drug Administration).
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
panasonic.net/id/pidsx/global
LASER
MARKERS
High-precision laser with a resolution of 1 μm 0.039 mil
PLC
The functionality of 500 displacement sensors in just a 12.5 mm 0.492 in wide device!
High speed multi-point sensing and stable appearance measurement in one device
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
The HL-D3 series was developed based on a new concept of capturing the shape of objects with “pointsˮ instead
of a “line.ˮ The new displacement sensors feature the following enhancements while not compromising the Z-axis
resolution:
FA COMPONENTS
1
■ Faster measurement, achieved by selecting only the desired sensing points
MACHINE VISION
SYSTEMS
2
■ Adjustable light intensity for each sensing point, which contributes to stable, precision detection
This is equivalent to the performance of 500 high-precision displacement sensors with a resolution of 1 μm 0.039 mil.
UV CURING
SYSTEMS
Measurement center distance and range (Z axis)
50 ±10 mm 1.969 ±0.394 in
Measurement range of width (X axis)
Selection
Guide
Laser
Displacement
Magnetic
12.5 mm 0.492 in
Sampling rate
Displacement
Contact
Displacement
Collimated
Beam Sensors
Metal-sheet
Double-feed Detection
Digital Panel
Controller
Max. speed 80 μs
(2-point specified)
Other Products
Conventional model
HL-D3
Resolution (Z axis)
HL-D3 uses parallel beams made possible by
the latest optical system. The reduced area of
shadow that appears when the emitted light
strikes the target object make it possible to
accurately ditermine the shape of the object.
HL-G1
HL-C2
HL-D3
1 μm 0.039 mil
(average number of samples: 64)
Ver.2
Upgraded version with enhanced functionality
Upgraded version of the HL-D3 series. Featuring added functions and a greater range of applications.
* Products produced from September 2013 have been upgraded to Ver. 2.
Main added functions
• X position correct function
• I/O terminal function
• OUT-OUT calculation
• Specular reflection coefficient setting
• Measurement area mask function