GS1T70-D540/2
ISDN DC-DC CONVERTER
PRELIMINARY DATA
Type
V
i
V
o
I
o
out 1 : 5V 72 mA
out 2 : 40V 12 mA
GS1T70-D540/2 28 to 115 V
FEATURES
Wide operating line termination voltage
Positive or negative input voltage polarity
Input and output filtering
Short-circuit protection on both outputs
Input power during shortcircuit within specifica-
tion
Minimum current drain during stand-by condition:
10µA for Vi<18V
Input-Output2 insulation voltage: 3000VRMS for
60 seconds
Output1-Output2 insulation voltage: 3000VRMS
for 60 seconds
Mechanical dimensions (L x W x H): 50.8 mm x
50.8 mm x 18 mm (2" x 2" x 0.71")
DESCRIPTION
In addition, the wide operating input voltage range
allows it to operate within the whole range of LT
(Line Termination) battery voltage and its relevant
line resistance.
The GS1T70-D540/2 converter has been designed
for the “U” interface of an ISDN-NTBA (Network
Termination Basic Access) system with either 4B3T
or 2B1Q standard trasmission.
3000V
isolation voltage for 60 second is pro-
RMS
vided between input to output 2 and between output
1 and output 2. No insulation is provided between
input and output 1.
Two outputs, 5V/72mA and 40V/12mA are sup-
plied.
The converter offers short-circuit protection (short-
circuit on 40V output doesn’t affect 5V output and
the input power never exceeds the limits of the
specification), input either voltage polarity, 80%
minimum efficiency at maximum load, input and
output filtering to meet very stringent noise require-
ments.
The design of the module has been conducted
using, as reference standards, the following:
EN 60950, VDE0878 part 1 class B (EMC),
EN55022 class B (EMC), CCITT 430, ETS 300 012
and ETS 300 047 (ISDN BASIC ACCESS, Safety
and Protection); anyway, please note that no certi-
fication processes have been carried out on the
module itself.
When the input voltage is below 18V, the converter
offers a very high input impedance and a maximum
quiescentcurrent of10µAaccording to thestandard
ETR 080.
20 January 1997
1/5