120W AC-DC Single Output Desktop
GS120 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.97
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
LED indicator for power on
No load power consumption<0.5W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
(except for 48V)
SPECIFICATION
GS120A20-
=R7B,P1M
GS120A24-
=R7B,P1M
GS120A48-
=R7B,P1M
ORDER NO.
GS120A12-R7B
GS120A15-R7B
SAFETY MODEL NO.
GS120A12
12V
GS120A15
15V
GS120A20
20V
GS120A24
24V
GS120A48
48V
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
8.5A
7A
6A
5A
2.5A
0 ~ 8.5A
102W
0 ~ 7A
105W
120mVp-p
5.0%
0 ~ 6A
120W
150mVp-p
5.0%
0 ~ 5A
120W
180mVp-p
3.0%
0 ~ 2.5A
120W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
240mVp-p
2.0%
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4 1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
4.0%
3.0%
2.0%
Note.6 2000ms, 30ms / 230VAC
2500ms, 30ms / 115VAC at full load
20ms / 230VAC
Note.7 85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
20ms / 115VAC at full load
FREQUENCY RANGE
POWER FACTOR (Typ.)
PF>0.97 / 230VAC
87.5%
PF>0.99 / 115VAC at full load
R7B
P1M
89%
-----
89%
88.5%
90%
91%
INPUT
EFFICIENCY (Typ.)
-----
89.5%
90.5%
AC CURRENT
1.4A / 115VAC
70A / 230VAC
0.75mA / 240VAC
0.7A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
105 ~ 160% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
RTH2 100 10
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P: 3KVAC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC EMISSION
EMC
(Note. 5)
Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B, FCC PART 15, EN61000-3-2,3, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
EMC IMMUNITY
MTBF
400.7Khrs min. MIL-HDBK-217F(25
167*67*35mm (L*W*H)
)
DIMENSION
OTHERS
0.62Kg; 20pcs/13.4Kg/0.9CUFT
PACKING
PLUG
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
CONNECTOR
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
4.Line regulation is measured from low line to high line at rated load.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS120-SPEC 2012-03-06