GPHP SERIES SINGLE OUTPUT POWER SUPPLY
High Power Supplies 600/700 Watt AC/DC Universal Input Power Supply
SUMMARY
g
• 90 -264 Vac nominal input range
• Overvoltage and short circuit protection
• Approved to UL, CSA and EN Standards
• Power Good LED
• Low Leakage
The GPHP Series are universal input AC/DC power supplies
with power factor correction (PFC) with up to 700 Watts ouput
power. The GPHP product in corporates ‘hot-swap’ capabilities
and a handle. The series is approved to EN60950 to reduce
design-in time and end system compliance costs
GPHP 600 shown in CRA rack
All specifications are typical at nominal input, full load at 25 OC unless otherwise stated
SPECIFICATIONS
OUPUT SPECIFICATIONS
INPUT SPECIFICATIONS
Output Power
Total Regulation
Rise time
Integral forced air
700 Watts max.
See table
Input Voltage range
Universal input
100-240 nom (85 - 264 max)
Vac
Input frequency
47 Hz to 63 Hz
25 A max.
160 mA
At turn-on
2.0 s max.
Input surge current
Ground Leakage current
Input current
Transient response
Main output 25%
0.1 A/ms
3.5% max. dev. 350 ms recovery
to 1%
264 Vac 60 Hz
120 Vac
Temperature Coef-
+/-0.03%/oC
8.5 A
ficient
230 Vac
4.5 A
Overvoltage protection
125% +/-10%
Yes
Input fuse
F1,F2
10.0 A
Short Circuit protection block wall
EMC INFORMATION
ENVIRONMENTAL SPECIFICATIONS
Conducted emissions
Radiated emissions
Line freq. harmonics
Voltage fluctuations
ESD Air
FCC Pt 15, EN55022 Level B
Thermal Performance
operating ambient
(see ratings chart)
-20 oC -50 oC
FCC Pt 15, EN55022 Level A
non-operating
0 - 50 oC
Convection cooled
-40 to +85 oC
600 Watts
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-2
Class A
Complies (clause 5b)
8 kV contact
6 kV air
Maximum Altitude
operating / non-operating
10,000 ft. / 40,000
ft. max.
ESD Contact
Relative Humidity
non-condensing
0.003 g2/Hz
5% - 95% RH
Radiated immunity
EN61000-4-3
3 V/m
Vibration (operating)
1.5 grms 3 axes 10
min/axis
Fast Transients (EFT) EN61000-4-4
2 kV 5 kHz
Line surge immunity
Conducted immunity
EN61000-4-5
EN61000-4-6
1 kV diff /2 kV cm
3 Vrms
Vibration (non-operating)
0.026 g2/Hz
5.0 grms 3 axes, 1
hr/axis
Power freq. mag. field EN61000-4-8
Voltage dip immunity EN61000-4-11
3 A/m
Shock
Shock
half-sine 20 gpk
half-sine 40 gpk
10 ms, 3 axes, 6
shocks total
Unit will ride through without
loss of output at 75% of
rated load with AC power fail
warning.
10 ms, 3 axes, 6
shocks total
Page 1 of 3