描述
AC-DC Power Supplies 150/180/250/350 Watts

GCS350PS56 数据手册

 浏览型号GCS350PS56的Datasheet PDF文件第2页浏览型号GCS350PS56的Datasheet PDF文件第3页浏览型号GCS350PS56的Datasheet PDF文件第4页浏览型号GCS350PS56的Datasheet PDF文件第5页浏览型号GCS350PS56的Datasheet PDF文件第6页浏览型号GCS350PS56的Datasheet PDF文件第7页 
AC-DC Power Supplies  
GCS Series  
150/180/250/350 Watts  
• Convection/Forced-cooled Ratings  
• Universal 85 - 264 VAC Input  
• IT & Medical Safety Approvals (Class I & II)  
• < 0.5 W Standby Power (150 & 180 Models)  
• -40° C to +70° C Operation  
• Remote On/Off  
• Class B Emissions  
• 3 Year Warranty  
Dimensions:  
The GCS Series has been designed to minimise the no load power consumption and maximise  
efficiency in order to facilitate equipment design to the latest environmental legislation.  
GCS150/GCS180/GCS250/GCS350:  
5.00 x 3.00 x 1.42” (127.0 x 76.2 x 36.3 mm)  
(-C): 5.50 x 3.48 x 1.70” (139.7 x 88.5 x 43.2 mm)  
(-TF): 5.50 x 3.48 x 2.20” (139.7 x 88.5 x 57.8 mm)  
(-EF): 6.35 x 3.48 x 1.70” (161.3 x 88.5 x 43.2 mm)  
(350-EF): 6.00 x 3.50 x 1.75” (152.4 x 88.9 x 44.4 mm)  
Approved for Class I and Class II applications, this range of single output AC-DC power supplies  
are packaged in an industry standard 3.0" x 5.0" x 1.42" package and achieves EN55011/22  
Level B emissions compliance whilst maintaining very low earth leakage currents, making them  
suitable for a wide range of 1U and other industrial, IT and medical applications.  
The series has single output versions from 12 V to 56 VDC, dual-fusing for compliance with IEC60601-1 and feature minimal excess heat  
generation as efficiencies reach 94%. They will deliver up to 350 W of power over an operating range of -40 °C and up to +70 °C and are  
available with a number of cover options.  
Models & Ratings  
Output Current V1  
Output Voltage (Vfan)  
& Current  
(1,2,3,4,5)  
Output Voltage V1  
Max Output Power  
Model Number  
Convection-cooled(6)  
Forced-cooled(8)  
12.5 A  
10.0 A  
6.3 A  
12.0 VDC  
15.0 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
12.0 VDC  
15.0 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
12.0 VDC  
15.0 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
56.0 VDC  
12.0 VDC  
15.0 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
56.0 VDC  
9.2 A  
7.3 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
12.0 VDC/0.6 A  
157 W  
157 W  
157 W  
157 W  
157 W  
187 W  
187 W  
187 W  
187 W  
187 W  
232 W  
232 W  
257 W  
257 W  
257 W  
257 W  
350 W  
350 W  
350 W  
350 W  
350 W  
350 W  
GCS150PS12  
GCS150PS15  
GCS150PS24  
GCS150PS28  
GCS150PS48  
GCS180PS12  
GCS180PS15  
GCS180PS24  
GCS180PS28  
GCS180PS48  
GCS250PS12  
GCS250PS15  
GCS250PS24  
GCS250PS28  
GCS250PS48  
GCS250PS56  
GCS350PS12  
GCS350PS15  
GCS350PS24  
GCS350PS28  
GCS350PS48  
GCS350PS56  
4.6 A  
3.9 A  
2.3 A  
12.5 A  
10.0 A  
6.3 A  
5.4 A  
3.1 A  
15.0 A  
12.0 A  
7.5 A  
5.4 A  
3.2 A  
15.0 A  
12.0 A  
7.5 A  
6.4 A  
3.7 A  
18.8 A  
15.0 A  
10.4 A  
8.9 A  
6.4 A  
3.7 A  
3.2 A  
16.7 A  
13.3 A  
8.3 A  
7.1 A  
5.2 A  
4.5 A  
29.2 A  
23.4 A  
14.6 A  
12.5 A  
7.3 A  
4.2 A  
3.6 A  
6.25 A  
Notes  
1. Add suffix -C for convection cooled cover, e.g. GCS150PS12-C.  
2. Add suffix -EF for fan cooled cover with end fan e.g. GCS150PS12-EF. Note Vfan  
output no longer available.  
convection cover or GCS150PS12-REF/GCS150PS12-RTF with fan covers,  
(remote on/off is standard on GCS350 models).  
5. GCS250PS12-C & GCS250PS15-C models derate 20% when convection cooled.  
6. GCS350 convection rating quoted at 40 °C, others at 50 °C.  
7. GCS350-C models derate 15% when convection-cooled at 40 °C.  
8. 7 CFM required to meet stated current for GCS150/180/250 and 15 CFM for GCS350.  
3. Add suffix -TF for fan cooled cover with top fan, e.g. GCS150PS12-TF. Note Vfan  
output no longer available.  
4. Add suffix -R for remote on/off, e.g. GCS150PS12-R, GCS150PS12-RC with  
www.xppower.com  
1

与GCS350PS56相关器件

型号 品牌 获取价格 描述 数据表
GCSS5580 GPSEMI

获取价格

STATIC SWITCH FOR POWER FACTOR
GCS抽出式低压开关柜 HF

获取价格

低压开关柜
GCTTLDL025AMX ETC

获取价格

Logic IC
GCTTLDL025AMY ETC

获取价格

Logic IC
GCTTLDL050AMX ETC

获取价格

Logic IC
GCTTLDL050AMY ETC

获取价格

Logic IC
GCTTLDL075AMX ETC

获取价格

Logic IC
GCTTLDL075AMY ETC

获取价格

Logic IC
GCTTLDL100AMX ETC

获取价格

Logic IC
GCTTLDL100AMY ETC

获取价格

Logic IC