Features :
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.90
No load power consumption<1W
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: TUV / UL / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
( for GC220Axx-AD1 only)
ORDER NO.
OUTPUT CONNECTOR
SAFETY
GC220Axx-R7B (standard model)
GC220Axx-AD1 (optional model)
4pin power din
TUV / CB / FCC / CE
UL / TUV / CB / FCC / CE
Anderson connector
GC220Axx-
xx=12,24,48 ; =R7B,AD1
SPECIFICATION
ORDER NO.
GC220A12-
GC220A24-
GC220A48-
SAFETY MODEL NO.
GC220A12
13.6V
GC220A24
27.2V
GC220A48
54.4V
DC VOLTAGE (Typ.)
RECOMMENDED BATTERY
80 ~ 200Ah
40 ~ 125Ah
8A
20 ~ 65Ah
CAPACITY
Note.2
OUTPUT
CONTINUOS OUTPUT
CURRENT (Typ.)
13.5A
4A
RATED POWER
183.6W
217.6W
217.6W
LED INDICATOR
Charging(CC) : RED
Floating charging(CV) : GREEN
VOLTAGE RANGE
Note.3 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
47 ~ 63Hz
PF>0.90 / 230VAC
89%
PF>0.98 / 115VAC at full load
92.5%
INPUT
93%
4A / 115VAC
120A / 230VAC
1.5mA / 240VAC
2A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
90 ~ 110% rated output power
OVERLOAD
Note.4
Protection type : Constant current limiting recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
Protection type : Shut down o/p voltage, re-power on to recover
95
10 (TSW1) detect on heatsink of power transistor
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +60 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +85 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.03% / (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012 (for GC220Axx-AD1 only), TUV EN60950-1 approved
I/P-O/P: 3KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMC
(Note. 5)
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B
Compliance to EN61000-3-2,3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
190Khrs min. MIL-HDBK-217F(25
210*85*46mm (L*W*H)
)
DIMENSION
PACKING
PLUG
OTHERS
1.1Kg; 12pcs/14.2Kg/0.73CUFT(GC220Axx-R7B)
1.2Kg; 12pcs/15.4Kg/1CUFT(GC220Axx-AD1)
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
CONNECTOR
CABLE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
3. Derating may be needed under low input voltage. Please check the derating curve for more details.
4. Constant current operation region is within 50~100% rated output voltage.
NOTE
5. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that whole system complies with the
EMC directives.
File Name:GC220-SPEC 2010-12-17