■Electrical Characteristics (Ta = 25°C)
MOS FET Relays
G3VM-61CR1 G3VM-101CR G3VM-201CR G3VM-401CR G3VM-601CR
G3VM-61FR1 G3VM-101FR G3VM-201FR G3VM-401FR G3VM-601FR
Item
Symbol
Unit
Measurement conditions
Minimum
Typical
1.5
1.64
1.8
LED forward voltage
Reverse current
VF
V
IF=10 mA
Maximum
Maximum
IR
10
μA VR=5 V
pF V=0, f=1MHz
Capacitance between
terminals
CT
Typical
Typical
70
G3VM-61CR1/FR1 : IO=1 A
0.28
5
0.3
5
0.3
5
0.2
1
0.23
5
G3VM-101CR/FR : IO=1 A
mA G3VM-201CR/FR : IO=1 A
G3VM-401CR/FR : IO=0.4 A
G3VM-601CR/FR : IO=0.6 A
Trigger LED forward
current
IFT
Maximum
Minimum
Typical
G3VM-61CR1/FR1 : IOFF=1 μA
G3VM-101CR/FR : IOFF=1 μA
mA G3VM-201CR/FR : IOFF=1 μA
G3VM-401CR/FR : IOFF=10 μA
G3VM-601CR/FR : IOFF=1 μA
0.01
Release LED forward
current
IFC
0.19
0.022
0.05
-
0.19
3
0.17
1.3
2
G3VM-61CR1/FR1 : IO=1 A, IF=5 mA, t < 1 s
G3VM-101CR/FR : IO=1 A, IF=5 mA, t < 1 s
G3VM-201CR/FR : IO=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : I
G3VM-601CR/FR : I
G3VM-61CR1/FR1 : I
G3VM-101CR/FR : IO=1 A, IF=5 mA, t < 1 s
G3VM-201CR/FR : IO=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : IO=0.4 A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=0.6 A, IF=2 mA, t < 1 s
Typical
0.06
0.15
0.25
0.5
Connection
A
O
=0.4 A, I
=0.6 A, I
=1 A, I
F
=2 mA, t < 1 s
Maximum
5
O
F=5 mA, t < 1 s
O
F=2 mA, t < 1 s
Maximum
resistance
with
Connection
B
RON
Ω
Maximum
Maximum
0.025
0.013
0.075
0.075
0.25
0.25
2.5
1.3
1
output ON
G3VM-61CR1/FR1 : IO=1 A, IF=2 mA, t < 1 s
G3VM-101CR/FR : IO=1 A, IF=5 mA, t < 1 s
G3VM-201CR/FR : IO=1 A, IF=5 mA, t < 1 s
G3VM-401CR/FR : IO=0.8 A, IF=2 mA, t < 1 s
G3VM-601CR/FR : IO=1.2 A, IF=2 mA, t < 1 s
Connection
C
0.5
Typical
0.01
10
0.02
1
0.1
1
0.001
1
0.05
10
Current leakage when
the relay is open
ILEAK
COFF
CI-O
μA VOFF=Load Voltage Ratings
pF V=0, f=1 MHz
Maximum
Capacitance between
terminals
Typical
Typical
850
2.5
720
400
0.8
410
4,300
Capacitance between I/O
terminals
pF f=1 MHz, VS=0 V
Minimum
Typical
1,000
108
Insulation resistance
between I/O terminals
RI-O
MΩ VI-O=500 VDC, ROH=60%
Typical
1.5
5
0.25
0.22
1
0.8
3
Turn-ON time
Turn-OFF time
tON
Maximum
Typical
IF =5 mA, RL =200 Ω, VDD=20 V
(See note 2.)
ms
0.1
0.08
0.07
tOFF
Maximum
1
Note: 2. Turn-ON and Turn-OFF Times
IF
2
5
RL
IF
VDD
VOUT
3
8
90%
VOUT
10%
tON
tOFF
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
G3VM-61CR1 G3VM-101CR G3VM-201CR G3VM-401CR G3VM-601CR
G3VM-61FR1 G3VM-101FR G3VM-201FR G3VM-401FR G3VM-601FR
Item
Symbol
Unit
V
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
Maximum
Typical
48
5
80
5
160
5
320
2
480
5
IF
IO
mA
A
Maximum
Maximum
Minimum
Maximum
25
1.5
-40
85
5
3
0.4
0.6
Ta
°C
■Spacing and Insulation
Item
Minimum
7.0
Unit
Creepage distances
Clearance distances
Internal isolation thickness
7.0
mm
0.4
3