G3VM-601G1
Ultrasensitive MOS FET Relays in 600-V Load series
for electric power saving.
MOS FET Relays
• Continuous load current of 70 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■Application Examples
■
Terminal Arrangement/Internal Connections
4
3
• Communication equipment
• Test & Measurement equipment
• Security equipment
Mold pin
mark *
OMRON logo
-601G1
Model name
932
LOT.No.
Pin 1 mark
• Amusement equipment
• Industrial equipment
1
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
• Various battery-driven devices
■List of Models
Minimum package quantity
Model
Load voltage
(peak value) *
Package type Contact form
Terminals
Number per tube Number per tape and reel
G3VM-601G1
100
-
-
1a
SOP4
Surface-mounting Terminals
600 V
(SPST-NO)
G3VM-601G1 (TR)
2,500
* The AC peak and DC value are given for the load voltage.
■Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
IF
Rating
30
1
Unit
mA
A
Measurement conditions
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
IFP
100 μs pulses, 100 pps
ΔIF/°C
VR
−0.3
5
mA/°C Ta ≥ 25°C
V
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
TJ
125
600
70
−0.7
°C
V
mA
VOFF
IO
ΔIO/°C
IOP
mA/°C Ta ≥ 25°C
A
0.21
t = 100 ms, Duty = 1/10
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
TJ
125
°C
Vrms
°C
°C
°C
VI-O
Ta
Tstg
-
1500
−40 to +85
−55 to +125
260
AC for 1 min
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
With no icing or condensation
With no icing or condensation
10 s
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum Unit
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 70 mA
LED forward voltage
Reverse current
VF
IR
1.1
-
-
-
-
-
-
-
1.27
-
30
-
35
1
75
0.8
-
1.4
10
-
0.2
60
1000
-
-
-
10
5
V
μA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Note: 2. Turn-ON and Turn-OFF Times
IF
1
4
RL
VDD
Capacity between terminals
Trigger LED forward current
Maximum resistance with output ON
Current leakage when the relay is open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminals
Turn-ON time
CT
VOUT
2
3
IFT
RON
ILEAK
Coff
CI-O
RI-O
tON
IF
= 0.5mA, IO = 70 mA, t < 1 s
VOFF = 600 V
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
IF = 0.5 mA, RL = 200 Ω,
VDD = 10 V (See note 2.)
IF
1000
-
-
90%
VOUT
2
10%
tON
tOFF
Turn-OFF time
tOFF
1