PISCES II DC/DC CONVERTERS
48V Input – 1.2VDC – 60A Output
POWER PRODUCTS
G2PW1V260
Isolation Specifications
Parameter
Min
2250
2000
500
Typical
Max
Units
Isolation Test Voltage, Input/Output (Basic)
Isolation Test Voltage, Input/Case
Isolation Test Voltage, Output Case
Isolation Resistance
V
DC
V
DC
V
DC
10
MΩ
Features
Parameter
Min
Typical
Max
Units
2
Over Temperature Protection, Thermal Sensor, Latching
Switching Frequency, Fixed
110
C
˚
250
kHz
2. PCB less than 130˚ C.
Approvals and Standards
General Specifications
Operating Temperature
UL and c-UL Recognized Component, TUV**,
UL60950, CSA 22.2 No. 950, IEC/EN 60950
-40 C to + 100 C
˚
˚
Storge Temperature
Relative Humidity
Vibration
-55 C + 125 C
˚
˚
EMC Characteristics:
10% to 95% RH, Non-condensing
Designed to meet emission and immunity
requirements per EN55022, CISPR 22,
Class B, and CISPR 24.
2 to 9 Hz, 3mm disp., 9 to 200 Hz, 1g
Material Flammability
Weight
UL V-0
35 grams
** An external fuse shall be used to comply with
the requirements.
MTBF Telcordia (Bellcore)
1.6 million hours
©2006 Bel Fuse Inc. Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com
page 3