描述
Absolute encoders - SSI

G1M2H.010A102 数据手册

 浏览型号G1M2H.010A102的Datasheet PDF文件第1页浏览型号G1M2H.010A102的Datasheet PDF文件第2页浏览型号G1M2H.010A102的Datasheet PDF文件第4页 
Absolute encoders - SSI  
Hollow shaft max. ø50.8 mm  
Optical multiturn encoder 13 bit ST / 12 bit MT  
G1M2H, G2M2H - SSI  
Terminal significance  
Terminal assignment  
UB  
Encoder voltage supply.  
Connector  
Pin 1  
Core colour Assignment  
GND  
Data+  
Encoder ground connection relating to UB.  
brown  
black  
blue  
UB  
Positive, serial data output of differential  
linedriver.  
Pin 2  
GND  
Pin 3  
Clock+  
Data+  
Zero setting  
Data-  
Data-  
Negative, serial data output of differential  
linedriver.  
Pin 4  
beige  
green  
yellow  
violet  
Pin 5  
Clock+  
Positive SSI clock input.  
Pin 6  
Clock+ together with clock- forms a current  
loop. A current of approx. 7 mA towards  
clock+ input means logic 1 in positive logic.  
Pin 7  
Clock-  
Pin 8  
brown/yellow DATAVALID  
pink UP/DOWN  
black/yellow DATAVALID MT  
Clock-  
Negative SSI clock input.  
Pin 9  
Clock- together with clock+ forms a current  
loop. A current of approx. 7 mA towards  
clock- input means logic 0 in positive logic.  
Pin 10  
Pin 11  
Pin 12  
Zero setting  
Input for setting a zero point anywhere  
within the programmed encoder resolution.  
The zero setting operation is triggered by a  
High impulse and has to be in line with the  
selected direction of rotation (UP/DOWN).  
Connect to GND after setting operation for  
maximum interference immunity. Impulse  
duration >100 ms.  
Please use cores twisted in pairs (for  
example clock+ / clock-) for extensi-  
on cables of more than 10 m length.  
8
1
9
10  
12  
2
3
7
6
11  
4
5
DATAVALID  
Diagnostic output.  
An error warning is given at level Low.  
Important: Interferences must be filtered by  
the downstram electronics.  
Trigger level  
SSI  
Circuit  
DATAVALID MT Diagnostic output for monitoring the  
multiturn sensor voltage supply. Upon  
SSI-Clock  
SSI-Data  
Optocoupler  
Linedriver RS485  
dropping below a defined voltage level the  
DV MT output is switched to Low.  
UP/DOWN  
UP/DOWN counting direction input.  
This input is standard on High. UP/DOWN  
means ascending output data with clock-  
wise shaft rotation when looking at flange.  
UP/DOWN-Low means ascending values  
with counterclockwise shaft rotation when  
looking at flange.  
Control inputs  
Input level High  
Input level Low  
Input resistance  
Input circuit  
>0.7 UB  
<0.3 UB  
10 kΩ  
www.baumerivo.com  
3

与G1M2H.010A102相关器件

型号 品牌 获取价格 描述 数据表
G1M2H.012A102 IVO

获取价格

Absolute encoders - SSI
G1M2H.110A102 IVO

获取价格

Absolute encoders - SSI
G1M2H.112A102 IVO

获取价格

Absolute encoders - SSI
G1MF YANGJIE

获取价格

SMAF
G1MFQ YANGJIE

获取价格

SMAF
G1MFS YANGJIE

获取价格

SMAF
G1MH YANGJIE

获取价格

SOD-123FL
G1MMH IVO

获取价格

Absolute encoders - modular bus covers
G1MMH.2203P32 IVO

获取价格

Absolute encoders - modular bus covers
G1MMH.2205P32 IVO

获取价格

Absolute encoders - modular bus covers