Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses

FRN-R 数据手册

 浏览型号FRN-R的Datasheet PDF文件第2页浏览型号FRN-R的Datasheet PDF文件第3页浏览型号FRN-R的Datasheet PDF文件第4页浏览型号FRN-R的Datasheet PDF文件第5页浏览型号FRN-R的Datasheet PDF文件第6页 
Effective February 2016  
Supersedes July 2013  
Technical Data1019  
Fusetron™ FRN-R Class RK5 250Vac/125Vdc  
1⁄10-60A, dual element, time-delay fuses  
Catalog numbers (amps) — non-indictaing fuses  
FRN-R-1⁄10  
FRN-R-1⁄8  
FRN-R-1-8⁄10  
FRN-R-2  
FRN-R-8*  
FRN-R-9*  
FRN-R-15⁄100  
FRN-R-2⁄10  
FRN-R-1⁄4  
FRN-R-2-1⁄4  
FRN-R-2-1⁄2  
FRN-R-2-8⁄10  
FRN-R-3  
FRN-R-10*  
FRN-R-12*  
FRN-R-15*  
FRN-R-17-1⁄2*  
FRN-R-20*  
FRN-R-25*  
FRN-R-30*  
FRN-R-35*  
FRN-R-40*  
FRN-R-45*  
FRN-R-50*  
FRN-R-60*  
FRN-R-3⁄10  
FRN-R-4⁄10  
FRN-R-1⁄2  
FRN-R-3-2⁄10  
FRN-R-3-1⁄2  
FRN-R-4  
FRN-R-6⁄10  
FRN-R-8⁄10  
FRN-R-1  
FRN-R-4-1⁄2  
FRN-R-5  
Catalog symbols:  
•ꢀ  
FRN-R-_ (non-indicating)  
FRN-R-1-1⁄8  
FRN-R-1-1⁄4  
FRN-R-1-4⁄10  
FRN-R-1-1⁄2  
FRN-R-1-6⁄10  
FRN-R-5-6⁄10  
FRN-R-6  
•ꢀ  
FRN-R-_ID (indicating)  
FRN-R-6-1⁄4  
FRN-R-7  
Description:  
Eaton Bussmann® series advanced protection,  
energy efficient FRN-R Class RK5 dual element,  
current-limiting, time-delay fuses with optional  
open fuse indication on select ratings. Time-delay  
– 10 seconds (minimum) at 500% of rated current  
(8 seconds for 1⁄10-30A sizes).  
FRN-R-7-1⁄2  
* Open fuse indication available by inserting the sufix “ID.”  
E.g., FRN-R-15ID.  
Carton Quantity:  
Amp rating  
Carton qty.  
1⁄10 – 60  
10  
Specifications:  
Ratings  
Features:  
•ꢀ  
Volts  
•ꢀ  
Provides motor overload, ground fault and  
short-circuit protection  
•ꢀ 250Vac  
•ꢀ 125Vdc  
•ꢀ  
•ꢀ  
•ꢀ  
•ꢀ  
Helps protect motors against burnout from  
overloads  
•ꢀ  
Amps 1⁄10-60A  
Helps protect motors against burnout from  
single-phasing on three-phase systems  
•ꢀ  
Interrupting rating  
•ꢀ 200kA Vac RMS Sym.  
•ꢀ 20kA Vdc  
Simplifies and improves blackout prevention  
(selective coordination)  
Dual-element fuses can be applied in circuits  
subject to temporary motor overloads and surge  
currents to provide both high performance  
short-circuit and overload protection  
Agency information  
•ꢀ  
UL Listed, Std. 248-12, Class RK-5, Guide  
JDDZ, File E4273  
•ꢀ  
•ꢀ  
The overload element provides protection  
against low level overcurrent of overloads  
and will hold an overload which is five times  
greater than the ampere rating of the fuse for a  
minimum of ten seconds  
CSA Certified, C22.2 No. 248.12, Class 1422-  
02, File 53787  
•ꢀ  
CE