Low Voltage Supplementary Fuses
Pin indication Fuses
GBA
MIC & MIN
FNA
GLD
Specifications
Class: Supplemental
Specifications
Class: Supplemental
Description: Fast-
acting, pin indication
fuse.
Specifications
Class: Supplemental
Description: Time-delay,
pin indication fuse.
Description: Fast-acting, pin
Dimensions: 13⁄32” x 1 ⁄
2
”
1
indication fuse.
Dimensions:
1
(10.3 x 38.1mm).
Dimensions: 1⁄
4
” x 1 ⁄
4”
13
1
⁄
32” x 1 ⁄ ” (10.3 x
2
Construction: Fiber tube
Ratings:
(6.6 x 31.7mm) 3AG.
38.1mm) 5AG.
Construction: Fiber tube
Ratings:
Construction:
Fiber tube
Ratings:
1
8
Volts — 250Vac ( ⁄10- ⁄10A)
— 125Vac (1-15A)
— 32V (20-30A)
Volts — See Agency Info below
Amps — ⁄
1
2
-15A
Volts — 250Vac (1-15A)
— 32V (20-30A)
Amps — 1-30A
1
Amps — ⁄10-30A
IR — See Agency Info below
1
8
IR — 35A ( ⁄10- ⁄10A @ 250Vac)
Agency Information: CE, Std. 248-
14, UL Listed, 0-5A/125Vac, 10,000
AIC, Guide JDYX, File E19180, UL
Recognized, 6A/125Vac, 1000AIC
8-15A/50Vac/dc, 300 AIC Guide
JDYX2, File E19180, CSA Certified:
0-5A/125Vac, 10,000 AIC Class
1422-01, File 53787.
1
— 10,000A ( ⁄10-15A @ 125Vac)
— 1000A (20-30A @ 32V)
IR — 35A (1A @250Vac)
— 100A (2-3A @250Vac)
— 200A (5-10A @250Vac)
— 750A (15A @250Vac)
— 10,000A (20-30A @32V)
— 35A (1A @250Vac)
Agency Information: CE, Std. 248-
1
8
14, UL Listed ⁄10- ⁄10A, IR 35A@ 250V,
IR 10kA@ 125V , 1-15A, IR 10kA@
125V, Guide JDYX, File 19180, CSA
8
Certified, 0- ⁄10A/250V, 1-10A/125V,
Class 1422-01, File 53787.
Features and Benefits
• Type GBA has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster
troubleshooting (reduced circuit
downtime).
• Type GLD has an plated pin to
activate transmitting a electrical
signal to indicate the location of
opened circuits, resulting in reduced
downtime.
Agency Information: CE, Std. 248-14,
MIC—0-15A UL Listed, Guide JDYX,
File E19180, MIN—1-5A CSA Certified,
Class 1422-01, File 53787.
Features and Benefits
• FNA has a pin indicator providing
visual identification of failed circuits,
resulting in reduced circuit downtime.
• Time-delay response allows close
sizing on control transformers and
relays
Features and Benefits
• Type MIN has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster trouble
shooting (reduced circuit downtime).
• Type MIC has silver-plated pin transmit-
ting an electrical signal indicating
location of a failed circuit, resulting in
faster troubleshooting (reduced circuit
downtime).
Typical Applications
• Control Circuits
• Electronic Circuits
Typical Applications
• Control Circuits
• Electronic Circuits
Catalog Numbers (Amps)
1
8
1
1
4
10
10
2
FNA- ⁄
FNA- ⁄
FNA-2 ⁄
FNA-2 ⁄
FNA-3
FNA-3 ⁄
FNA-3 ⁄
FNA-4
FNA-4 ⁄
FNA-5
FNA-6 ⁄
FNA-7
FNA-8
1
8
8
10
FNA- ⁄
FNA-1
FNA-1 ⁄
FNA-1 ⁄
FNA-1 ⁄
FNA-1 ⁄
FNA-1 ⁄
FNA-1 ⁄
FNA-2
Typical Applications
• Control Circuits
15
1
8
GLD Catalog Numbers (Amps)
100
FNA- ⁄
1
GLD- ⁄
2
GLD-2
GLD-3
GLD-4
GLD-5
GLD-6
2
1
2
10
4
10
2
FNA- ⁄
FNA-9
3
1
4
1
GLD- ⁄
4
GLD-10
GLD-12
GLD-15
• PLC Circuits
4
10
FNA- ⁄
FNA-10
FNA-12*
FNA-15*
FNA-20*
FNA-25*
FNA-30
3
1
GLD-1
• Electronic Circuits
10
2
FNA- ⁄
1
4
6
1
GLD-1 ⁄
2
MIC Catalog Numbers (Amps)
FNA- ⁄
10
10
2
1
8
MIC-1
MIC-2
MIC-3
MIC-5
MIC-20
MIC-25
MIC-30
2
10
FNA- ⁄
6
6
MIC-10
MIC-15
10
10
FNA- ⁄
FNA-5 ⁄
FNA-6
GBA Catalog Numbers (Amps)
1
3
1
GBA- ⁄
2
GBA-2
GBA-3
GBA-4
GBA-5
GBA-8
4
4
FNA- ⁄
FNA-2 ⁄
3
GBA- ⁄
4
GBA-10
GBA-15
*12-30A versions are dual-tube construction
MIC - (1-15)UL Listed 125Vac / IR = 10kA
GBA-1
1
GBA-1 ⁄
2
MIN Catalog Numbers (Amps)
MIN-1
MIN-2
MIN-5
MIN-20
MIN-10
MIN-25N
Recommended signal block for
Recommended fuse blocks/fuse
Recommended signal block for
13
1
1
1
⁄
32” x 1 ⁄
2” indicating fuses
13
1
2
holders for ⁄ ” x 1 ⁄ ” indicating fuses
4
4
⁄
32” x 1 ⁄ ” indicating fuses
• Page 41
Data Sheet: 2047
• Page 41
Data Sheet: 2012
• Page 41
Data Sheet: 2029
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
47