IEC Inlet Filters FN 9266
DATASHEET
High Performance Power Entry Module with Switch
Rated currents up to 10 A
Approvals
High quality 2-pole rocker switch
Optional reduced leakage current versions (A/B
type)
Complies with IEC/EN 60601-1
Snap-in versions (S type)
High attenuation performance
The FN 9266 power entry module combines an IEC
inlet, mains filter with very high filter attenuation
based on nano crystalline material selection and a
switch in a small form factor. Choosing FN 9266
product line brings you rapid availability of a standard
filter associated with the necessary safety
Performance indicators
acceptances. Standard IEC connector filters are a
practical solution helping you to pass EMI system
approval in a short time. A wide selection on
amperage ratings, mounting possibilities and filters
for medical applications (acc. to IEC 60601-1 with low
leakage current and high performance) are designed
to offer you the desired solution.
Features and benefits
Excellent conducted attenuation performance,
based on chokes with high saturation resistance
and good thermal behavior
Technical specifications
High quality 2-pole rocker switch for all-pole
disconnection
250 VAC, 50/60 Hz
DC to 400 Hz
Operating voltage
Operating frequency
Rated currents
Faston terminals for easy assembly
1 to 10 A @ 40°C max.
FN 9266 B versions comply with the requirements of
1MOP acc. to IEC/EN 60601-1 for creepage and
clearance, leakage current and high potential
testing
P –> PE 2000 VAC for 2 sec (Standard)
P –> PE 2500 VAC for 2 sec (B-types)
P –> N 760 VAC for 2 sec
High potential test voltage
IP 40 according to IEC 60529
-25°C to +85°C (25/85/21)
Protection category
As flange mount and snap-in types available
Temperature range (operation and storage)
Design corresponding to
UL 60939-3, CSA Std C22.2 No. 8, IEC/EN 60939-3, GB/T
15287, GB/T 15288
Typical applications
Inlet plastic: UL 94 V-0
Flammability corresponding to
Switch plastic: UL 94 V-0
Medical electrical devices (MD) and In-Vitro
Diagnostic (IVD) medical devices
2,100,000 hours
MTBF @ Rated amb. Temp./Voltage (Mil-
HB-217F)
Portable electrical and electronic equipment
EDP and office equipment
Rocker switch description
Function
2-pole, dark not illuminated
Marking I – 0
Single-phase power supplies
Switch-mode power supplies
Inrush current 100 A
Electrical specifications
50,000 on-off operations for 10 A according to EN
610581-1
Test and measurement equipment
Switch ratings
Europe (ENEC)
Typical electrical schematic
10 A (4 A), 250 VAC* 5E4
16 A (4 A), 250 VAC* 1E4
20 A, 125 VAC 1 HP; 250 VAC 2 HP;
USA (UL)
* Value in () relates to the inductive current charge: cosφ = 0.65