FF-SRS5925 Dual channel Emergency Stop Module  
FF-SR Series  
FEATURES  
Complies with EU Directive for machines  
98/37/EC, IEC 204, EN 60204, DIN VDE  
0113  
(Pending)  
Dual channel input  
S
uitable for interfaces  
up to  
Output: two NO contacts and one NC  
contact  
CATEGORY 4  
per EN 954-1  
Switching current from 1mA to 7A (5 µm  
gold plated contacts allow low current)  
Automatic start or manual start modes  
Line fault detection and detection of  
blocked start push button  
Selectable cross fault detection in  
emergency stop control circuit  
LED indicates power and the status of  
both internal relays  
Mechanical life up to ten million  
operations  
Electrical life up to one million  
operations  
Voltage drop protection  
Removable terminal strips for ease of  
maintenance  
The FF-SRS5925 Emergency Stop modules are designed to be used in emergency  
stop circuits when danger to personnel or machinery is present. This slim housing  
device has two safety relays with positive-guided contacts to ensure redundancy.  
In the manual start mode, the module accepts input from the safety device (light  
curtain, safety mat, safety switches, etc) between S11/S12 and S21/S22 after acti-  
vation of the push-button between S33 and S34; then, the normally open safety  
contacts (13/14, 23/24) will close and the normally closed contact (31/32) will  
open.  
In the automatic start mode, the module accepts immediate input from the safety  
device (light curtain, mat, safety switches, etc) between S11/S12 and S21/S22; if  
S33/S34 are jumpered, the normally open safety contacts (13/14, 23/24) will close  
and the normally closed contact (31/32) will open.  
Slim housing 22,5 mm / 0.89 in width  
In either mode, if the safety device is actuated (emergency stop condition occurs),  
the normally open contact will open immediately and the normally closed contact  
will close. This emergency stop condition is relayed via the safety contacts of the  
module to the machine control circuitry to arrest dangerous motion and/or remove  
power.  
APPLICATIONS  
Emergency-stop circuits on machines  
Door protection  
Conveyors/transfer lines  
Use with Type 3 or Type 4 Electro-  
sensitive Protective Equipment for:  
Cross fault monitoring must be used when two independent safety inputs are pro-  
vided to this module to increase the overall safety level of the solution (see typical  
application examples).  
- Point-of operation protection  
- Perimeter/zone guarding protection  
!
WARNING  
MISUSE OF DOCUMENTATION  
The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system  
installation information.  
Complete installation, operation and maintenance information is provided in the instructions supplied with each product.  
Failure to comply with these instructions could result in death or serious injury.  
FF-SRS5925  
Industrial Safety Products •  
201  

与FF-SRS59252相关器件

型号 品牌 获取价格 描述 数据表
FF-SRS59342 HONEYWELL

获取价格

Analog Circuit
FF-SRS5934E HONEYWELL

获取价格

Analog Circuit
FF-SRS59352 HONEYWELL

获取价格

Analog Circuit,
FF-SRS5935G HONEYWELL

获取价格

Analog Circuit
FF-SRS5939 HONEYWELL

获取价格

Analog Circuit
FF-SRS59392 HONEYWELL

获取价格

Analog Circuit
FF-SRT011F2 HONEYWELL

获取价格

Analog Circuit
FF-SRT011FE HONEYWELL

获取价格

Analog Circuit
FF-SRT011FG HONEYWELL

获取价格

Analog Circuit
FF-SRT011R2 HONEYWELL

获取价格

Analog Circuit