5秒后页面跳转
FF-SR059362 PDF预览

FF-SR059362

更新时间: 2024-01-30 04:34:53
品牌 Logo 应用领域
霍尼韦尔 - HONEYWELL /
页数 文件大小 规格书
4页 104K
描述
Analog Circuit,

FF-SR059362 技术参数

是否Rohs认证: 符合生命周期:Active
Reach Compliance Code:unknownHTS代码:8542.39.00.01
风险等级:5.6Base Number Matches:1

FF-SR059362 数据手册

 浏览型号FF-SR059362的Datasheet PDF文件第1页浏览型号FF-SR059362的Datasheet PDF文件第2页浏览型号FF-SR059362的Datasheet PDF文件第3页 
APPLICATION EXAMPLE  
Door protection using key operated interlock switch (GKR/GKL Series) and standstill monitor module (FF-SR05936)  
L1  
L2  
L3  
Fuse  
Honeywell  
GKR/GKL  
Solenoid Key  
Fuses  
Sw2-21 Sw2-13 Sw1-21 Sw1-13 Term4  
Operated Safety  
Interlock Switch  
Key  
Sol.  
K4  
K5  
Sw2-22 Sw2-14 Sw1-22 Sw1-14 Term5  
Door  
Opening  
Start Motor  
push-button  
Emergency  
Stop  
K5  
K4  
Unlock  
Door  
M
3 Ph.  
Stop Motor  
push-button  
A1  
11  
21  
33 43  
Z1  
Z2  
A1  
S
S
S
(+)  
(+)  
11  
12  
22 13 23 33  
41  
Honeywell  
FF-SR05936  
Honeywell  
FF-SRS5935  
Power  
Power  
S1  
Zero  
Motion  
Con-  
tinuity  
Z1/Z2  
K4  
K5  
K2  
K3  
S2*  
Internal  
switches  
A2  
(-)  
A2  
(-)  
S
S
S21  
PE 14 24 34 42  
12  
22  
34 44  
33  
34  
K4  
K5  
N (-)  
FUNCTIONAL DESCRIPTION  
Stop Sequence  
Start Sequence  
Initially, the motor is operating and the door is closed and locked.  
Initially, the motor is not operating and the door is open. To initiate the  
start sequence, close the door. This action will close the two normally  
closed contacts of the key operated interlock switch. It will also  
automatically restart the emergency stop modules. As the Unlock  
push-button is open, the solenoid coil of the key operated interlock  
switch is de-energized and the door is locked.  
To initiate the stop sequence, press the Stop push-button. This  
action will de-energize the external safety relays K4 and K5 and im-  
mediately stop the motor.  
To unlock the door when the motor has reached zero motion, press  
the Unlock push-button. This action will energize the coil of the  
solenoid of the key operated interlock switch and unlock the door.  
The door may now be opened safely. No hazardous motor motion  
is present.  
The motor may now be started.  
To start the motor, press the Start push-button. This action will ener-  
gize the self-maintained external relays K4 and K5, and will start the  
motor.  
Emergency stop Sequence  
In case of an emergency stop situation, the two channel inputs of the  
FF-SRS5935 emergency stop control module will open. This action  
de-energizes the external safety relays K4 and K5, stopping the  
motor. All other steps remain the same as described above (Stop Se-  
quence).  
232  
Industrial Safety Products •  
FF-SR05936  

与FF-SR059362相关器件

型号 品牌 描述 获取价格 数据表
FF-SR05936E HONEYWELL Analog Circuit,

获取价格

FF-SR05936G HONEYWELL Analog Circuit

获取价格

FF-SR259802 HONEYWELL Analog Circuit

获取价格

FF-SR25980E HONEYWELL Analog Circuit

获取价格

FF-SR25980G HONEYWELL Analog Circuit

获取价格

FFS-R32A3 JDSU Fused Coupler, Visible Light

获取价格