DC AXIAL FAN
60x60x25mm
FAD1-06025 Series
Features:
Motor: Brushless DC
Motor Protection: IC
Bearing Type: Two Ball, Sleeve, or Hydro Dynamic
Connection: UL 1007 AWG 24, 320mm Wire Leads
Frame Material: Plastic UL94V-0
Impeller Material: Plastic UL94V-0
Operating Temp:
Two Ball: -10°C~70°C
Sleeve: -10°C~60°C
Hydro Dynamic: -10°C~70°C
Life Expectancy:
Two Ball: 70,000 Hours
Sleeve: 30,000 Hours
Hydro Dynamic: 50,000 Hours
Fan-S Division
Rated
Speed
Maximum
AirFlow
Maximum Static
Pressure
Noise
Level
Volt.
Current
Power
(W)
Weight
Model No.
(InAq)
(mmAq)
(rpm)
(CMM)
(CFM)
(VDC)
(A)
(g)
(dB/A)
*
5
0.08
0.40
2500
0.373
13.200
17.880
24.330
13.200
17.880
24.330
27.880
31.400
13.200
17.880
24.330
27.880
0.063
0.125
0.207
0.063
0.125
0.207
0.242
0.320
0.063
0.125
0.207
0.242
1.600
18.1
53.0
FAD1-06025B LW12
*
5
0.17
0.35
0.04
0.08
0.13
0.21
0.30
0.07
0.06
0.08
0.10
0.506
0.688
0.373
0.506
0.688
0.789
0.888
0.373
0.506
0.688
0.789
27.9
36.3
18.1
27.9
36.3
37.6
42.9
18.1
27.9
36.3
37.6
53.0
53.0
53.0
53.0
53.0
53.0
53.0
53.0
53.0
53.0
53.0
0.85
1.75
0.48
0.96
1.56
2.52
3.60
1.68
1.44
2.88
2.40
3500
4500
2500
3500
4500
5000
6100
2500
3500
4500
5000
3.175
5.257
1.600
3.175
5.257
6.146
8.128
1.600
3.175
5.257
6.146
FAD1-06025B MW12
*
5
FAD1-06025B HW12
*
12
12
12
12
12
24
24
24
24
FAD1-06025C LW12
*
FAD1-06025C MW12
*
FAD1-06025C HW12
*
FAD1-06025C JW12
FAD1-06025CBKW12
*
FAD1-06025D LW12
*
FAD1-06025D MW12
*
FAD1-06025D HW12
*
FAD1-06025D JW12
Noise is measured at the distance of one (1) meter from the axis of intake.
* Indicates “B” (Ball Bearing), “S” (Sleeve), or “H” (Hydro Dynamic)
J
K
ualtek
Q
www.qualtekusa.com
ISO-9001 Company
Electronics Corporation