Single Beam Sensor (1 Beam: 100 mm)
EY3A-110-A
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
■ Features
• Ensures higher sensitivity and external light interference resistivity
than any other photomicrosensor.
• Narrow sensing range ensures stable sensing of a variety of sens-
ing objects.
Center of
positioning boss
Center of detector
2-R2
41.6 0.1
2.7 0.1
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
VCC
VOUT
IOUT
Rated value
8.3 dia
3.05
.
Power supply voltage
7 V
7 V
5 dia.
Load voltage
Load current
dia.
10
dia.
10 mA
Center of emitter
Pin No. 1
4
Ambient
temperature
Operating
Storage
Topr
Tstg
0°C to 60° C
–15°C to 70° C
3.6
Note: Make sure there is no icing or condensation when operating the
Sensor.
30 0.1
17
1
C
58
64.4
■ Ordering Information
0
3.2−0.2 dia.
Description
Single beam sensor
Model
EY3A-110-A
Pin no. Remarks
Name
1
2
3
O
V
Output (OUT)
Power supply (Vcc)
Ground (GND)
G
Unless otherwise specified, the
tolerances are as shown below.
Dimensions
3 mm max.
Tolerance
0.3
3 < mm ≤ 6
0.375
0.45
6 < mm ≤ 10
10 < mm ≤ 18
18 < mm ≤ 30
30 < mm ≤ 50
50 < mm ≤ 80
0.55
0.65
Recommended Mating Connectors:
Tyco Electronics AMP 173977-3 (press-fit connector)
179228-3 (crimp connector)
0.8
0.95
175778-3 (crimp connector)
■ Electrical and Optical Characteristics (Ta = 0°C to 60°C)
Item
Power supply voltage
Value
Condition
5 V 5%
---
Current consumption
50 mA max.
VCC = 5 V, RL = ∞
VCC = 5 V, RL = ∞
Peak current consumption
Low-level output voltage
High-level output voltage
Response delay time (high to low)
200 mA max.
0.6 V max.
3.5 V min.
VCC = 5 V, IOL = 4 mA (see note 1)
VCC = 5 V, RL = 4.7 kΩ (see note 2)
1.5 ms max.
The time required for the output to become “Lo” after placing
sensing object.
Response delay time (low to high)
1.5 ms max.
The time required for the output to become “Hi” after removing
sensing object.
Note: 1. These conditions are for the sensing of lusterless paper with an OD of 0.9 maximum located at the correct sensing position of the Sensor
as shown in the optical path arrangement on the next page.
2. These conditions are for the sensing of the paper supporting plate with an OD of 0.05 located using the glass plate without paper as
shown in the optical path arrangement on the next page.
134
Single Beam Sensor (1 Beam: 100 mm) EY3A-110-A