60 Watts
xppower.com
ECP Series
•
•
•
•
•
•
•
Low Profile Design
Compact Size, 4” x 2”
IT & Medical Approvals
Single, Dual and Triple Output
<0.5 W No Load Input Power
Peak Load Capability
3 Year Warranty
Specification
Input
General
Input Voltage
• 85-264 VAC, derate from 100% load at
90 VAC to 90% load at 85 VAC
• 47-63 Hz
• 0.85 A max at 115 VAC
• 100 A max at 230 VAC, cold start at 25 °C
• EN61000-3-2, class A
Efficiency
Isolation
• 88% typical at 230 VAC and full load
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 30-130 kHz variable
• >400 kHrs to MIL-HDBK-217F
at 25 °C, GB
Input Frequency
Input Current
Inrush Current
Power Factor
Switching Frequency
MTBF
No Load Input Power • <0.5 W
Earth Leakage Current • <250 µA at 264 VAC, 60 Hz
Environmental
Input Protection
• Internal T2 A/250 V fuse in both
line and neutral
Operating Temperature • -20 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
• Natural convection
• 5% to 95% RH, non condensing
• 3000 m max
Output
Operating Humidity
Operating Altitude
Output Voltage
• See table
Output Voltage Trim
•
10% on V1 only, output 2 on multi output
models will track by the same percentage
Storage Temperature • -40 °C to +85 °C
Shock
• 30 g pk, half sine, 6 axes
• 2 g rms, 5 Hz to 500 Hz, 3 axes
Minimum Load
• 10% minimum load required on all
outputs of multi output models
Vibration
Start Up Delay
Start Up Rise Time
Hold Up Time
• 1.3 s max
• 15 ms typical
• 16 ms min at full load at 115 VAC
EMC & Safety
Emissions
• EN55011/22, level B conducted & level A
radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, 4 kV indirect contact,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
Total Regulation
• Output 1: 2% from 0% load to 100% load
Output 2: 5% from 20% load to 100% load
Output 3: 5% from 10% load to 100% load
• Fitted to US05 version, compensates for
0.5 V drop
• 4% max deviation, recovering to less than
1% within 500 µs for 50% step load
change at 1 A/µs
• 1% pk-pk (2% for US05 version),
measured with 20 MHz bandwidth
Harmonic Currents
Voltage Flicker
ESD Immunity
Remote Sense
Transient Response
Radiated Immunity
EFT / Burst
Surge
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
Ripple & Noise
Conducted Immunity
Dips & Interruptions
Overvoltage Protection • 115-140% of nominal output voltage
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
on V1 only, recycle input to reset
• 120-160% of nominal power
Overload Protection
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
Perf Criteria A, A, A, B
•
0.02%/°C max
Safety Approvals
• EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No.60601-1 Including Risk
Management, IEC60601-1