AC-DC Power Supplies
ECE60 Series
60 Watts
• Ultra Compact Size
• Single Outputs from 3.3 to 48 V
• Encapsulated
• PCB & Chassis Mount Versions
• <0.3 W No Load Input Power
• -40 to +70 °C Operation
• Peak Load Capability
• 3 Year Warranty
Dimensions:
The ECE60 series of compact encapsulated AC-DC power modules are available in both PCB &
chassis mount versions offering exceptional power density of >10W/in . Output voltages are
available from 3.3 – 48 VDC and these “green power” modules offer high active mode efficiency
and low no load power consumption. They also provide a peak load capability up to 130% of
nominal power for up to 30s and a wide operating temperature range from -40 to +70°C.
ECE60:
3
3.60 x 1.50 x 1.10” (91.4 x 38.1 x 28.0 mm)
ECE60-S:
4.45 x 1.57 x 1.12” (113.0 x 40.0 x 28.5 mm)
Models & Ratings
Output Current
(4)
(2,3)
Output Power
Output Voltage
Efficiency
Model Number
(1)
Nominal
10.00 A
10.00 A
6.67 A
5.00 A
4.00 A
2.50 A
1.67 A
1.25 A
Peak
33 W
50 W
60 W
60 W
60 W
60 W
60 W
60 W
3.3 V
5.0 V
13.00 A
13.00 A
8.67 A
6.50 A
5.20 A
3.25 A
2.17 A
1.63 A
79%
83%
87%
87%
88%
89%
88%
86%
ECE60US03
ECE60US05
ECE60US09
ECE60US12
ECE60US15
ECE60US24
ECE60US36
ECE60US48
9.0 V
12.0 V
15.0 V
24.0 V
36.0 V
48.0 V
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power.
2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE60US12-S.
3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix ‘D’, e.g. ECE60US24-SD. DIN Rail mounting clip is available as a separate item, order
code ECE60 DIN CLIP.
4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input.
Summary
Characteristic
Minimum
85
Typical
Maximum
264
Units
VAC
VDC
W
Notes & Conditions
Input Range
Derate load from 100% at 90 VAC to 90% at 85 VAC
120
370
<0.3
<0.5
87
12-36 V versions
No Load Input Power
Efficiency
W
3.3-9 V & 48 V versions
See note 4 above
79
89
%
Some specification parameters may not met below -25 °C.
Derate linearly from 100% load at +50 °C to 50% load at
70 °C.
Operating Temperature
-40
+70
°C
EMC
EN55022 Level B Conducted & Radiated, EN61000-4, EN61000-3
EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL
Safety Approvals
www.xppower.com