5/10 Watts
ECE Series
xppower.com
•
•
•
•
•
•
•
Ultra Compact Size
Single Outputs from 3.3 to 48 V
Encapsulated PCB Mount
<0.3 W No Load Input Power
Peak Load Capability
No External Components Required
3 Year Warranty
Specification
Input
General
Input Voltage
• 85-264 VAC (120-370 VDC) derate load
Efficiency
• See tables
from 100% at 90 VAC to 90% at 85 VAC
• 47-63 Hz
• ECE05: 0.1 A rms at 230 VAC
ECE10: 0.2 A rms at 230 VAC
Isolation
• 4000 VAC Input to Output
• 130 kHz typical
Input Frequency
Input Current
Switching Frequency
Power Density
3
• ECE05: 8.3 W/In
3
ECE10: 11.1 W/In
Inrush Current
Power Factor
• 20 A at 115 VAC, 40 A at 230 VAC,
cold start at 25 °C
• EN61000-3-2 Class A
MTBF
• >450 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Earth Leakage Current • Class II construction no earth
No Load Input Power • <0.3 W
Input Protection
Operating Temperature • -25 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
• Convection-cooled
• Internal T1 A/250 VAC fuse
Cooling
Operating Humidity
• 95% RH, non-condensing
Output
Storage Temperature • -40 °C to +85 °C
Operating Altitude
Vibration
• 3048 m, 10,000 ft
• 2 g, 10 Hz to 500 Hz, 10 mins/cycle,
60 mins each cycle
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
• See tables
•
1%
• No minimum load required
• 2 s max
• 25 ms max
• 8 ms/40 ms typical at full load and
115/230 VAC
EMC & Safety
Start Up Rise Time
Hold Up Time
Emissions
• EN55022, level B conducted & radiated*
• EN61000-3-2, EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
Harmonic Currents
ESD Immunity
Radiated Immunity
Line Regulation
•
0.5% max
Load Regulation
Transient Response
•
1% max
• 4% max deviation, recovery to within
1% in 500 µs for a 25% load change
• 3.3-5 V versions: 60 mV pk-pk, all other
models 1% pk-pk max 20 MHz bandwidth
EFT/Burst
Surge
Ripple & Noise
• EN61000-4-5, installation Class 3,
Perf Criteria A
Overvoltage Protection • 125-190%, 195-216% ECE10US03
Overload Protection • 125-190%
Short Circuit Protection • Trip and restart (hiccup mode)
Conducted Immunity
Magnetic Fields
Dips & Interruptions
• EN61000-4-6, 10 Vrms Perf Criteria A
• EN61000-4-8, 10 A/m Perf Criteria A
• EN61000-4-11, 30% for 10 ms,
60% for 100 ms, 100% for 5000 ms
Perf Criteria A, B, B
Temperature
Coefficient
• 0.05%/°C
Safety Approvals
• EN60950-1, UL60950-1,
CSA22.2 No. 234 per cUL
Notes
* If output is connected to GND, please contact applications engineering for further information.