E2EL
E2EL
Specifications
Brass type
Type
∅6,5
M8
M12
M18
M30
Operating voltage
Rated supply voltage
Current consumption
Sensing object
10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
Mounting ((s)hielded,
s
n
s
n
s
s
n
s
s
n
s
n
(n)on–shielded) (see note 1)
Operating distance in mm
1,5
2,0
1,5
2,0
2,0
4,0
4,0
5,0
8,0
8,0
10,0
15,0
Tolerance of operating distance
10%
6,5x6,5x1
Standard target size in mm
(L x W x H in mm, FE 37)
8x8x1
12x12x1
18x18x1 24x24x1
30x30x1 45x45x1
Differential travel
1 % ... 15 % of operating distance
5,0 5,0 2,0
Max. response frequency in kHz
Control output Type
0,6
1,0
0,5
0,3
0,5
0,25
0,15
E2EL–... E1 type: NPN–NO
E2 type: NPN–NC
F1 type: PNP–NO
F2 type: PNP–NC
Max–Load
Max–on–state
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Voltage drop
Circuit protection
Indicator
Reverse polarity, output short–circuit
Operating indicator (yellow LED)
Operating: –25° to 70°C
Ambient temperature
Humidity
35 to 95 % RH
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
10 % max. of Sn at 23°C in temperature range of –25° to 70°C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947–5–2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Shock
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions
resistance
Enclosure
rating
IP 67 (EN 60947–1)
2
Connection
(see note 2)
Pre–wired
Connector
2 m PVC–cable, 3 x
0,14 mm@
2 m PVC–cable, 3 x 0,25 mm
2m PVC–cable, 3 x
0,5 mm
2
M8 plug
M8 plug
M12 plug
M12 plug
Weight in g
Material
Pre–wired
long
45
50
48
15
13
75
70
25
20
115
100
60
260
200
155
110
short
43
Connector long
short
10
8
50
Case
Brass
PBTP
Sensing face
Note: 1. For detailed mounting instruction please refer to page 11.
2. PUR cable and different length on request.
3