www.uk.tdk-lambda.com/dtm
• ErP1, CEC2 and EISA3 Compliant Models
• Wide Range AC Input
• Medical Certifications
Key Market Segments & Applications
Medical, Industrial Computing,
Life Sciences / Laboratory
DTM110-C Series
90W to 110W Medical AC-DC External Power Supplies
DTM110-C Features and Benefits
Features
• CEC and EISA Compliant
• Wide Range AC Input
• 87% Average Efficiency
Benefits
• Easier system compliance
• Global Operation
• Consumes less energy
Specifications
MODELS
DTM110PWxxx-C
ITEMS
Input Voltage range
Inrush Current
VAC
90 - 264VAC (47 - 63Hz)
A
A
100A at 230VAC input, 25°C ambient cold start
Input Current
2A at 90VAC, Full Load
Power Factor
-
Meets EN61000-3-2. >0.9 PF
Leakage Current (264VAC 60Hz)
Hold Up Time (Typ)
Temperature Coefficient
Voltage Accuracy
Adjustment Range
Minimum Load
µA
ms
%/°C
%
V
Typically 300µA
>10ms
0.05%/°C
1%
None
A
None
Total Regulation
Ripple & Noise
%
%
-
12V to 15V Models: 5%, >15V models 3%
1%
Short Circuit Protection
Overvoltage Protection
Average Efficiency
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
<160% - hiccup mode
V
110 - 150% of nominal (Cycle input power to reset)
%
°C
°C
%RH
-
87%
0 to +40°C
-10 to +70°C
10 - 90%RH
Convection
Withstand Voltage
Vibration (non operating)
Shock
Safety Agency Approvals
Safety Class
Altitude
VAC
-
Input to Ground 1.5kVAC, Input to Output 4kVAC
23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
-
< 196.1 m/s2 (20G)
-
CE, UL60601-1, EN60601-1, IEC60601-1
-
Class I
m
W
-
3000m
Offload Power Consumption
Conducted & Radiated EMI
Immunity
< 0.5W
EN60601-1-2, FCC Part 18 Class B
-
g
EN55011
Weight (Typ)
605g
Size (WxLxH)
mm
mm
-
170 x 64.8 x 38.5
Cable Length
1050mm
AC Input Connector
Output Connector
Warranty
IEC 320-C14 (Accepts IEC 320-C13)
-
Kycon KPPx-4P or equivalent Pins 1 & 2: -Vout, Pins 3 & 4: +Vout
3
yrs
Notes: (1) ErP - Energy Related Products (2) Californian Energy Commission (3) EISA - Energy Independence and Security Act of 2007
1