DS2478
DeepCover Automotive Secure Coprocessor
Electrical Characteristics (continued)
(Limits are 100% tested at T = +25°C. Limits over the operating temperature range and relevant supply voltage range are guaranteed
A
by design and characterization. Specifications marked GBD are guaranteed by design and not production tested. Specifications to the
minimum and maximum operating temperature are guaranteed by design and are not production tested.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
4
UNITS
ms
Computation Time
(HMAC)
t
CMP
Generate ECC Key Pair
t
500
50
ms
GKP
GES
Generate ECDSA
Signature
t
ms
Verify ECDSA Signature
or Compute ECDH Time
t
160
50
ms
ms
ms
VES
TRNG Generation
t
RNG
ODC
TRNG On-Demand
Check
t
50
OTP
OTP Write Temperature
Data Retention
T
0
50
°C
OPTW
t
T
A
= +125°C (Note 12)
10
years
DR
Note 1: System requirement.
Note 2: OTP programming current production tested at +25°C.
2
Note 3: All I C timing values are referred to V
and V
levels.
IL(MAX)
IH(MIN)
Note 4: Guaranteed by design and/or characterization only. Not production tested.
Note 5: The I-V characteristic is linear for voltages less than 1V.
Note 6: I/O pins of the DS2478 do not obstruct the SDA and SCL lines if V
is switched off.
CC
Note 7: t
min = t
max + 200ns for rise or fall time + t
accordingly.
min. Values greater than these can be accommodated by
SU:DAT
LOW
HD:DAT
extending t
LOW
Note 8: The DS2478 provides a hold time of at least 100ns for the SDA signal (referenced to the V
of the SCL signal) to bridge
IH(MIN)
the undefined region of the falling edge of SCL.
2
Note 9: The DS2478 can be used in a standard-mode I C-bus system, but the requirement t
≥ 250ns must then be met. Also,
SU:DAT
2
the acknowledge timing must meet this setup time (I C Bus Specification Rev. 03, 19 June 2007).
Note 10: C = Total capacitance of one bus line in pF. The maximum bus capacitance allowable may vary from this value depending
B
2
on the actual operating voltage and frequency of the application (I C Bus Specification Rev. 03, 19 June 2007).
2
Note 11: I C communication should not take place for the max t
Note 12: Data retention is tested in compliance with JESD47G.
time following a power-on reset.
OSCWUP
www.analog.com
Analog Devices | 5