100W Single Output Industrial DIN Rail Power Supply
DR-100 series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
No load power consumption<1W
100% full load burn-in test
3 years warranty
..
SPECIFICATION
MODEL
DR-100-12
DR-100-15
DR-100-24
DC VOLTAGE
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
7.5A
6.5A
4.2A
0 ~ 7.5A
90W
0 ~ 6.5A
0 ~ 4.2A
100.8W
150mVp-p
24 ~ 29V
1.0%
97.5W
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE 12 ~ 15V
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p
OUTPUT
15 ~ 18V
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
2700ms, 80ms/230VAC
2700ms, 80ms/115VAC at full load
50ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
87%
18ms/115VAC at full load
124 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
INPUT
87%
89%
3A/115VAC
1.6A/230VAC
COLD START 30A/115VAC
45A/230VAC
105 ~ 135% rated output power
OVERLOAD
Note.6
Protection type : Constant current limiting, recovers automatically after fault condition is removed
16 ~ 20V 19 ~ 23V 30 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
90 15 (RTH2) detect on heatsink of power transistor
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
I/P-O/P:3KVAC
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN61204-3, EN55022 ClassB
Compliance to EN61000-3-2,-3
EMC
EMI CONDUCTION & RADIATION
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
486K hrs min. MIL-HDBK-217F (25
100*93*56mm (W*H*D)
)
OTHERS
NOTE
DIMENSION
PACKING
0.35Kg; 36pcs/13.6Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Harmonic current test @ 90% load.
6. Under short circuit or overload >150% conditions, output voltage may shut down for 5 sec. and then go into constant current protection mode.
File Name:DR-100-SPEC 2010-05-10