DG201HS
Vishay Siliconix
a
SPECIFICATIONS
Test Conditions
Unless Specified
V+ = 15 V, V- = - 15 V
A Suffix
- 55 to 125 °C - 40 to 85 °C
D Suffix
Tempb Typc Mind Maxd Mind Maxd Unit
V
IN = 3 V, 0.8 Vf
Parameter
Symbol
Analog Switch
Analog Signal Rangee
VANALOG
rDS(on)
Full
V-
V+
V-
V+
V
Ω
%
IS = - 10 mA, VD
=
8.5 V
Drain-Source
On-Resistance
Room
Full
25
50
75
50
75
V+ = 13.5 V, V- = - 13.5 V
r
DS(on) Match
Room
3
Room
Full
Room
Full
0.1
- 1
- 60
- 1
1
60
1
- 1
- 20
- 1
1
20
1
V+ = 16.5 V, V- = - 16.5 V
IS(off)
ID(off)
ID(on)
VD
=
15.5 V
Switch Off Leakage Current
0.1
0.1
VS= 15.5 V
nA
- 60
60
- 20
20
V+ = 16.5 V, V- = - 16.5 V
Channel On Leakage
Current
Room
Full
- 1
- 60
1
60
- 1
- 20
1
20
V
S = VD
=
15.5 V
Digital Control
VINH
VINL
Input, High Voltage
Input, Low Voltage
Input Capacitance
Input Current
Full
Full
Full
Full
2.4
- 1
2.4
- 1
V
0.8
1
0.8
1
CIN
5
pF
µA
IINH or IINL
VIN under test = 0.8 V, 3 V
Dynamic Characteristics
Room
Full
Room
Full
48
30
60
75
50
70
60
75
50
70
tON
Turn-On Time
RL = 1 kΩ, CL = 35 pF
VS
=
10 V, VINH = 3 V
See Figure 2
tOFF1
ns
Turn-Off Time
tOFF2
ts
Room
Room
150
180
Output Settling Time to 0.1 %
Charge Injection
CL = 1 nF, VS = 0 V
Vgen = 0 V, Rgen = 0 Ω
RL = 1 kΩ, CL = 10 pF
Q
Room
Room
- 5
85
pC
dB
Off Isolation
OIRR
f = 100 kHz
Any Other Channel Switches
RL = 1 kΩ, CL = 10 pF
Crosstalk
(Channel-to-Channel)
XTALK
Room
100
f = 100 kHz
CS(off)
CD(off)
CD(on)
Source Off Capacitance
Drain Off Capacitance
Channel On Capacitance
Room
Room
Room
8
8
VS , VD = 0 V, f = 1 MHz
pF
30
Drain-to-Source
Capacitance
CDS(off)
Room
0.5
Power Supplies
Room
Full
Room
Full
4.5
3.5
Positive Supply Current
I+
10
10
mA
V+ = 15 V, V- = - 15 V
VIN = 0 or 5 V
Negative Supply Current
Power Consumptionc
I-
- 6
- 6
PC
Full
240
240
mW
Notes:
a.Refer to PROCESS OPTION FLOWCHART.
b.Room = 25 °C, Full = as determined by the operating temperature suffix.
c.Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d.The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e.Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
Document Number: 70038
S-71241–Rev. G, 25-Jun-07
www.vishay.com
3