DG200A
Specificationsa
Test Conditions
A Suffix
B, C Suffix
Unless Otherwise Specified
–55 to 125_C
V+ = 15 V, V– = –15 V
f
V
= 2.4 V, 0.8 V
Parameter
Analog Switch
Symbol
Tempb
Typc
Mind Maxd Mind Maxd Unit
IN
e
Analog Signal Range
V
Full
–15
15
–15
15
V
ANALOG
Drain-Source
On-Resistance
Room
Full
45
70
100
80
100
r
V
= "10 V, I = –1 mA
W
DS(on)
D
S
Source Off
Leakage Current
Room
Full
–2
–100
2
100
–5
–100
5
100
I
V = "14 V, V = #14 V
"0.01
"0.01
"0.1
S(off)
D(off)
S
D
Drain Off
Leakage Current
Room
Full
–2
–100
2
100
–5
–100
5
100
I
V
= "14 V, V = #14 V
nA
D
S
Channel On
Leakage Current
Room
Full
–2
–200
2
200
–5
–200
5
200
I
V = V = "14 V
S D
D(on)
f
Digital Control
Room
Full
0.0009
0.005
–0.5
–1
–1
–10
V
= 2.4 V
IN
Input Current with
Input Voltage High
I
INH
Room
Full
0.5
1
1
10
V
= 15 V
= 0 V
mA
IN
Input Current with
Input Voltage Low
Room
Full
–0.0015
–0.5
–1
–1
–10
I
V
IN
INL
Dynamic Characteristics
Turn-On Time
Turn-Off Time
t
Room
Room
440
340
1000
425
1000
425
ON
See Switching Time Test Circuit
= 1000 pF, V = 0 V
ns
t
OFF
C
L
g
Charge Injection
Q
Room
–10
pC
R = 0 W
g
Source-Off Capacitance
Drain-Off Capacitance
C
V = 0 V
Room
Room
9
9
S(off)
S
f = 140 kHz
= 5 V
V
IN
C
D(off)
V
= 0 V
D
pF
C
C
+
S(On)
D(on)
Channel-On Capacitance
Off Isolation
V
= V = 0 V, V = 0 V
Room
Room
Room
25
75
90
D
S
IN
OIRR
V
L
IN
dB
Crosstalk
(Channel-to-Channel)
V = 2 V, f = 1 MHz
S
X
TALK
Power Supplies
Positive Supply Current
Negative Supply Current
I+
I–
Room
Room
0.8
2
2
Both Channels On or Off
= 0 V and 2.4 V
mA
V
IN
–0.23
–1
–1
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is aminimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f.
V
= input voltage to perform proper function.
IN
Siliconix
3
S-52880—Rev. B, 28-Apr-97