Power entry modules without line filter
DD21
www.schurter.com/pg05
IEC Appliance Inlet C14 with Line Switch 2-pole, Fuseholder 1- or 2-pole, for PCB mounting,
Standard or Medical Fuse drawer
C14
70° C
Description
Characteristics
- Panel Mount:
- Ultra-compact design. Ideal for low profile designs
- All single elements are already wired
Screw-on mounting on PCB from rear-side
- 3 Functions:
- For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
- Ideal for application with high transient loads
Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for
fuse-links 5 x 20 mm 1- or 2-pole
- PCB solder terminals
- With cover on rear-side
- Qualified for use in equipment according IEC/EN 60950
Approvals
- VDE Certificate Number: 40018283
- UL File Number: E93617
Other versions on request
- Fuse drawer 1-pole, plus spare fuse case
- Fuse drawer 2-pole, with shorting bar
- Other rocker marking
- Line switch 1-pole
- Protection class II, 70°C
- Without cover
References
Alternative: version with line filter DD22
Alternative: version for panel mounting DD11
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
RoHS, CHINA-RoHS, Mating Connectors, e-Shop, SCHURTER-Stock-
Check, Distributor-Stock-Check, CAD-Drawings, Accessories, Detailed
request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10A / 250VAC; 50Hz
10A / 125VAC; 60Hz ¹⁾
> 2.5kVAC between L-N
> 3kVAC between L/N-PE
(1min/50Hz)
Appliance Inlet
Fuseholder
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20mm
5 x 20: 2W (1 pole)/ 1.6W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical Details
Allowable Operation Temp.
Degree of Protection
Protection Class
-25°C to 85°C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
For PCB mounting 3 mm, Ground ter-
minal, additional quick connect 4.8 x
0.8 mm
Screw-on mounting: max 3mm
Mounting screw torque max 0.5Nm
Thermoplastic, black, UL 94V-0
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Terminal
Line Switch
Panel Thickness s
Material: Housing
1) with cover 8 A, without cover 10 A
Connectors
1