DCM™ in a VIA Package
DC-DC Converter
DCM3414x50M06A8yzz
S
®
C
NRTL US
C
US
Isolated, Regulated DC Converter
Features & Benefits
Product Ratings
VIN = 16 V to 50 V
POUT = 180 W
• Isolated, regulated DC-to-DC converter
• Up to 180 W, 36.00 A continuous
• 90.8% peak efficiency
VOUT = 5.0 V
(4.0 V to 5.5 V Trim)
IOUT = 36.00 A
• 103 W/in3 Power density
Product Description
• Wide input range 16 – 50 Vdc
The DCM in a VIA package is an Isolated, Regulated DC-to-DC
Converter, operating from an unregulated, wide range input to
generate an isolated 5.0 Vdc output. With its high frequency
zero voltage switching (ZVS) topology, the DCM converter
consistently delivers high efficiency across the input line range.
The DCM provides tight output voltage regulation and offers a
secondary-referenced control interface for trim, enable, and
remote sense operation. DCM converters and downstream DC-
DC products support efficient power distribution, providing
superior power system performance and connectivity from a
variety of unregulated power sources to the point-of-load.
• Safety Extra Low Voltage (SELV) 5.0 V Nominal Output
• ZVS high frequency switching
• Allows remote sense or local sense operation
• Tight regulation over all line and load conditions
• Fully operational current limit
• OV, OC, UV, short circuit and thermal protection
• Available in chassis mount and through hole VIA package
n 3.380” x 1.400” x 0.370”
The VIA package offers flexible thermal management options
with very low top and bottom side thermal impedances.
(85.93 mm x 35.5 mm x 9.30 mm)
Typical Applications
• Industrial
• Process control
• Automotive
• Heavy Equipment
Size:
3.380 x 1.400 x 0.370 in
85.93 x 35.5 x 9.30 mm
Part Ordering Information
Max
Input
Voltage
Max
Output Output
Voltage Power
Max
Product
Function
Package
Length
Package
Width
Package
Type
Range
Ratio
Product Grade
(Case Temperature)
Option Field
DCM
34
14
x
50
M
06
A8
y
z
z
DCM =
DC-DC
Converter
01 = Chassis/Analog
05 = Short Pin/Analog
09 = Long Pin/Analog
Length in
Width in
B = Board VIA
C = -20 to 100°C[1]
T = -40 to 100°C[1]
Internal Reference
Inches x 10 Inches x 10 V = Chassis VIA
[1] High Temperature Power Derating may apply, see Thermal Specified Operating Area, Figure 1 on Page 4.
DCM™ in a VIA Package