Specifications
□
□
(
)
Part number Flange size
(
)
(
)
DB21M142S-01 42
DB22M162S-01 60
(
)
±
%
Input source Note1
DC24 V 10
(
)
Getaway torque
A
2 MAX.
Class I
3 MAX.
Protection class
(
)
Operation environment
Installation category over-voltage category : II, pollution degree : 2
Applied standards
EN61010-1
Operating ambient temperature
+
℃
0 to 40
(
)
Note2
-
+
℃
Conservation temperature
Operating ambient humidity
Conservation humidity
Operation altitude
20 to 60
Basic
specifications
(
)
)
35 to 85%RH no condensation
Environment
(
10 to 90%RH no condensation
(
)
1000 m 3280 feet MAX. above sea level
Tested under the following conditions ; 4.9m/s2, frequency range 10 to 55Hz, direction along X, Y
and Z axes, for 2 hours each
Vibration resistance
Impact resistance
“
”
.
Not influenced at NDS-C-0110 standard section 3.2.2 division
C
Not influenced when 1500V AC is applied between power input terminal and cabinet for one
minute.
Withstand voltage
Insulation resistance
10M ohm MIN. when measured with 500V DC megohmmeter between input terminal and cabinet.
(
)
(
)
(
)
Mass Weight
0.5kg 1.10lbs
0.87kg 1.92lbs
Protection function
LED indicator
Against driver overheat
Function
Alarm monitor
Ω
Photo coupler input method, input resistance 220
(
)
Command pulse input signal Note3
“
”
“ ”
Input signal voltage :
H = 4.0 to 5.5V, L = 0 to 0.5V
Ω
Photo coupler input method, input resistance 470
(
)
Power down input signal PD
“
”
“ ”
Input signal voltage :
H = 4.0 to 5.5V, L = 0 to 0.5V
Ω
Photo coupler input method, input resistance 470
(
)
Step angle setting selection input EXT
“
”
“ ”
Input signal voltage :
H = 4.0 to 5.5V, L = 0 to 0.5V
Ω
Photo coupler input method, input resistance 470
(
)
FULL/HALF setting selection input F/H
“
”
“ ”
Input signal voltage :
H = 4.0 to 5.5V, L = 0 to 0.5V
I/O signals
Ω
Photo coupler input method, input resistance 470
EMG input signal
“
”
“ ”
Input signal voltage :
H = 4.0 to 5.5V, L = 0 to 0.5V
Open collector output by photo coupler
Output signal standard : Vceo = 30V MAX., Ic = 20mA MAX.
BUSY output signal
Open collector output by photo coupler
Output signal standard : Vceo = 30V MAX., Ic = 20mA MAX.
(
)
Phase origin monitor output signal MON
Open collector output by photo coupler
Output signal standard : Vceo = 30V MAX., Ic = 20mA MAX.
(
)
Alarm output signal AL
(
(
(
)
Note1 Note that the power voltage must not exceed 24VDC + 10% (26.4VDC).
)
Note2 If the driver is placed in a box, the temperature inside the box must not exceed this specified range.
)
Note3 The maximum input frequency is 250k pulse/s.
□
□
(
)
60mm 1.65inch
+.08
3.46 .00
88 +2
(
)
0
A
0.1
7±0.25(.27±.01)
1.5±0.25(.06±.01)
20.6±0.5(.81±.02)
0.025
60±0.5(2.36±.02)
47.1±0.13(1.85±.01)
+1
+.04
.59 .00
CN1:POWER
Manufacturer:JST
CONNECTOR:S02B-PASK-2
(
)
15
0
(EFFECTIVE
LENGTH)
0.075
A
R4MIN.
2
1
Useꢀproper
grounding
t
e
c
h
n
i
q
u
e
s
.
A
2・・・・20
1・・・・19
CN2:I/O
Manufacturer:JST
CONNECTOR:SM20B-SHLDS-GW-TF
+0.5
+.02
(
)
5.8±0.15(.23±.01)
4-φ4.5
0
4-φ.18 .00
EARTH TERMINAL
M2.5X0.45X4L
PS
RSW
DS
C
4
6