5秒后页面跳转
DA103JC PDF预览

DA103JC

更新时间: 2024-11-17 11:01:31
品牌 Logo 应用领域
村田 - MURATA 变压器音频变压器
页数 文件大小 规格书
3页 131K
描述
民用设备,工业设备

DA103JC 技术参数

是否Rohs认证: 符合生命周期:Active
包装说明:ROHS COMPLIANTReach Compliance Code:compliant
ECCN代码:EAR99风险等级:5.55
其他特性:TURNS RATIO: 1:1高度:6.35 mm
长度:9.52 mm安装特点:SURFACE MOUNT
最高工作温度:85 °C最低工作温度:-40 °C
包装方法:TUBE物理尺寸:L9.52XB9.0XH6.35 (mm)
表面贴装:YES变压器类型:GENERAL PURPOSE AUDIO TRANSFORMER
宽度:9 mmBase Number Matches:1

DA103JC 数据手册

 浏览型号DA103JC的Datasheet PDF文件第2页浏览型号DA103JC的Datasheet PDF文件第3页 
DA100 Series  
Transformers for Digital Audio Data Transmission  
SELECTION GUIDE  
Max.  
Leakage  
Primary  
Inductance  
(10kHz, 50mV)  
Isolation  
(Flash tested  
Inductance  
for 1 second)  
Order Code  
(100kHz, 10mV)  
mH  
μH  
Vμs  
15  
dB  
dB  
Vrms  
2000  
DA101C  
DA102C  
DA103C  
1:1  
1.00 - 1.59  
0.22  
46.80  
52.10  
FEATURES  
RoHS compliant  
1:1  
1:1  
2.00 - 3.00  
4.00 - 5.96  
0.39  
0.91  
20  
28  
40.40  
36.30  
49.70  
46.40  
Compatible with leading chip sets  
2kVrms isolation  
ORDER CODE DETAILS  
Industry-standard pinout  
Surface mount option  
UL 94 V-0 package materials  
Low profile  
Order Code  
Package Type  
Packaging Type  
Tube  
Quantity  
DAXXXC  
DAXXXMC  
DAXXXMC-R  
6 Pin DIL  
6 Pin SM  
6 Pin SM  
50  
50  
Tube  
Suitable for both 75 & 110Ω circuits  
Toroidal construction  
Compliant with AES/EBU standards  
Fully encapsulated  
Tape & Reel  
500  
ABSOLUTE MAXIMUM RATINGS  
Operating free air temperature range  
0°C to 70°C  
–40°C to 125°C  
Storage temperature range  
DESCRIPTION  
The Digital Audio Range of transformers is  
designed to improve the balance of transmitter  
and receiver circuitry in hi-fi equipment,  
video games and other applications requiring  
high-performance digital audio transmission.  
Compliant with AES/EBU recommendations for the  
digital audio interface, offering optimised shunt  
capacitance between primary and secondary  
windings. Capable of operating over the audio  
data rate frequency range, providing isolation from  
50-60Hz noise.  
All specifications typical at TA =25°C  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Volt-  
age’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ testing of a barrier component can actually degrade  
are all terms that relate to the same thing, a test voltage,  
applied for a specified time, across a component designed  
to provide electrical isolation, to verify the integrity of that  
isolation.  
It is well known that repeated high-voltage isolation  
isolation capability, to a lesser or greater degree  
depending on materials, construction and environ-  
ment. This series has toroidal isolation transformers,  
with no additional insulation between primary and  
secondary windings of enameled wire. While parts  
can be expected to withstand several times the  
stated test voltage, the isolation capability does de-  
pend on the wire insulation. Any material, including  
this enamel (typically polyurethane) is susceptible  
to eventual chemical degradation when subject to  
very high applied voltages thus implying that the  
number of tests should be strictly limited. We there-  
fore strongly advise against repeated high voltage  
isolation testing, but if it is absolutely required, that  
the voltage be reduced by 20% from specified test  
voltage.  
All products in this series are 100% production tested at  
their stated isolation voltage.  
A question commonly asked is, “What is the continuous  
voltage that can be applied across the part in normal opera-  
tion?”  
For a part holding no specific agency approvals both input  
and output should normally be maintained within SELV limits  
i.e. less than 42.4V peak, or 60VDC. The isolation test volt-  
age represents a measure of immunity to transient voltages  
and the part should never be used as an element of a safety  
isolation system. The part could be expected to function cor-  
rectly with several hundred volts offset applied continuously  
across the isolation barrier; but then the circuitry on both  
sides of the barrier must be regarded as operating at an  
unsafe voltage and further isolation/insulation systems must  
form a barrier between these circuits and any user-acces-  
sible circuitry according to safety standard requirements.  
This consideration equally applies to agency recog-  
nized parts rated for better than functional isolation  
where the wire enamel insulation is always supple-  
mented by a further insulation system of physical  
spacing or barriers.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232  
KMP_DA100C_C02 Page 1 of 3  

与DA103JC相关器件

型号 品牌 获取价格 描述 数据表
DA103JC-R MURATA

获取价格

民用设备,工业设备
DA103M CANDD

获取价格

Transformers for Digital Audio Data Transmission
DA103MC MURATA

获取价格

Transformers for Digital Audio Data Transmission
DA103MC-R MURATA

获取价格

Transformers for Digital Audio Data Transmission
DA103MR CANDD

获取价格

Transformers for Digital Audio Data Transmission
DA105-BW-W Carling Technologies

获取价格

Toggle Switch, SPST, On-off, Maintained, Wire Terminal, Toggle Bat Actuator, Panel Mount
DA105-PW-B Carling Technologies

获取价格

Toggle Switch, SPST, On-off, Maintained, Wire Terminal, Toggle Actuator, Panel Mount
DA106ERW MPD

获取价格

Analog Circuit
DA106K ROHM

获取价格

Rectifier Diode, 1 Element, 0.015A, 8V V(RRM), Silicon
DA106KT146 ROHM

获取价格

Rectifier Diode, 1 Element, 0.015A, Silicon