CY7C1358A/
GVT7164T18
Electrical Characteristics Over the Operating Range
Parameter
VIHD
VIH
Description
Input High (Logic 1) Voltage[9, 10]
Test Conditions
Data Inputs (DQxx)
Min.
2.0
2.0
–0.5
–1
Max.
Unit
V
VCC+0.5
All Other Inputs
4.6
0.8
1
V
VIl
Input Low (Logic 0) Voltage[9, 10]
Input Leakage Current[11]
Output Leakage Current
Output High Voltage[9, 12]
Output Low Voltage[9, 12]
Supply Voltage[9]
V
ILI
0V < VIN < VCC
µA
µA
V
ILO
Output(s) disabled, 0V < VOUT < VCC
IOH = –4.0 mA
–1
1
VOH
VOL
2.4
IOL = 8.0 mA
0.4
3.6
V
VCC
3.135
V
133
100
83
75
MHz/ MHz/ MHz/ MHz/
Parameter
Description
Conditions
Typ.
-4
-5
-6
-7
Unit
ICC
Power Supply
Current:
Device selected; all inputs < VILor > VIH;
cycle time > tKC min.; VCC = Max.;
outputs open
150
300
240
220
200
mA
Operating[13, 14, 15]
ISB2
ISB3
ISB4
CMOS Standby[14, 15] Device deselected; VCC = Max.;
all inputs < VSS + 0.2 or > VCC – 0.2;
5
10
20
80
10
20
70
10
20
60
10
20
50
mA
mA
mA
all inputs static; CLK frequency = 0
TTL Standby[14, 15]
Device deselected; all inputs < VIL
or > VIH; all inputs static;
10
40
VCC = Max.; CLK frequency = 0
Clock Running[14, 15] Device deselected;
all inputs < VIL or > VIH; VCC = Max.;
CLK cycle time > tKC min.
Capacitance[16]
Parameter
Description
Test Conditions
Typ.
Max.
Unit
CI
Input Capacitance
Input/Output Capacitance (DQ)
TA = 25°C, f = 1 MHz,
VCC = 3.3V
4
7
5
8
pF
pF
CO
Thermal Resistance
Description
Test Conditions
Symbol TQFP Typ.
Unit
Thermal Resistance (Junction to Ambient)
Thermal Resistance (Junction to Case)
Still Air, soldered on a 4.25 x 1.125 inch,
4-layer PCB
ΘJA
ΘJC
25
9
°C/W
°C/W
Notes:
9. All voltages referenced to VSS (GND).
10. Overshoot: VIH ≤ +6.0V for t ≤ tKC /2.
Undershoot:VIL ≤ –2.0V for t ≤ tKC /2.
11. Capacitance derating applies to capacitance different from the load capacitance shown in part (a) of AC Test Loads.
12. AC I/O curves are available upon request.
13. ICC is given with no output current. ICC increases with greater output loading and faster cycle times.
14. “Device Deselected” means the device is in Power-Down mode as defined in the truth table. “Device Selected” means the device is active.
15. Typical values are measured at 3.3V, 25°C, and 8.5-ns cycle time.
16. This parameter is sampled.
Document #: 38-05121 Rev. *A
Page 6 of 11