DATA SHEET • CX77144
POWER AMPLIFIER MODULE FOR CDMA (887–925 MHZ)
for achieving the electrical performance listed in Table 4. Table 5
shows the specifications for recommended operating conditions.
Table 3 lists the settings for the power ranges.
Electrical Specifications
The following tables list the electrical characteristics of the
CX77144 Power Amplifier. Table 1 shows the absolute maximum
ratings and Table 2 lists the recommended operating conditions
Table 1. Absolute Maximum Ratings (1)
Characteristic
Symbol
PIN
Minimum
—
Nominal
0.0
Maximum
7.0
Unit
dBm
Volts
Volts
°C
RF Input Power
Supply Voltage
Reference Voltage
VCC
—
3.5
6.0
VREF
TC
—
2.85
+25
—
3.1
(2)
Case Operating Temperature
–30
+85
Case Storage Temperature
(1)
TSTG
–55
+125
°C
No damage assuming only one parameter is set at limit at a time with all other parameters set at nominal value.
Case Operating Temperature refers to the temperature of the GROUND PAD at the underside of the package.
(2)
Table 2. Recommended Operating Conditions
Characteristic
Symbol
VCC1
Minimum
1.4
Nominal
3.5
Maximum
4.2
Unit
Supply Voltage
Volts
VCC2
1.4
3.5
4.2
VBIAS
VREF
3.2
3.5
4.2
PA ON
2.75
—
2.85
—
2.95
< 0.5
0.5
Reference Voltage
Volts
Volts
PA OFF
VREF
High Bias Mode VCONT
0.0
—
Mode Input Impedance > 2.5 kΩ
Low Bias Mode VCONT
2.5
—
3.0
Operating Frequency
FO
TC
887
–30
906
—
925
MHz
°C
(1)
Case Operating Temperature
+85
(1)
Case Operating Temperature refers to the temperature of the GROUND PAD at the underside of the package.
Table 3. Power Range Truth Table
Power Setting
High Power
VREF
2.85 V
2.85 V
0.0 V
VCONT
0.0 V–0.5 V
2.5 V–3.0 V
0.0 V
Output Power
18 dBm to 27 dBm
≤ 18 dBm
—
Low Power
Shut Down
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
June 9, 2004 • Skyworks Proprietary Information. • Products and product information are subject to change without notice. • 102047A
2