5秒后页面跳转
CT-26-6A PDF预览

CT-26-6A

更新时间: 2024-11-27 03:27:11
品牌 Logo 应用领域
伯恩斯 - BOURNS /
页数 文件大小 规格书
1页 184K
描述
Turns-Counting Dial

CT-26-6A 数据手册

  
Features  
27 mm and 28 mm diameter  
10 turns  
No backlash - mounted directly to  
potentiometer shaft  
For use with precision potentiometers or  
other rotating devices up to 10 turns  
High force, positive brake  
CT-23/CT-26 Turns-Counting Dial  
Mechanical and Physical Characteristics  
Number of Turns ..................................................................................................................................................................................0 to 10  
Readability - Over 10 Turns..........................................................................................................................................Within 1/500 of a turn  
Torque with Brake Engaged .....................................................................................................................9.88 N-cm (14.0 oz.-in.) maximum  
Markings .............................................................................................................................................................White on black background  
Locking Brake................................................................................................................................................................Yes, Positive, friction  
Weight.................................................................................................................................................................................34 grams (1.2 oz.)  
Set Screw ...........................................................................................................................................................ISO M3x 0.35, one included  
Set Screw Tightening Torque ...................................................................................................................16.94 N-cm (1.5 lbs.-in.) minimum  
Hex Key Size................................................................................................................................................................................1.5 mm hex  
Shaft and Bushing Requirements  
Shaft Diameter Requirements ........................................................................................................................................Refer to chart below  
Shaft Extension Beyond Face of Locator Plate................................................................................................11.05 mm (0.43 in.) minimum  
16.25 mm (0.63 in.) maximum  
Bushing Extension Beyond Face of Locator Plate............................................................................................4.00 mm (0.15 in.) maximum  
Bourns® Model CT-23, front of panel mounting, digital turns-  
counting dial saves valuable internal space. Highly accurate, it will  
enhance the man/machine interface of any control panel. Easy to  
read white on black numerals provide excellent legibility and  
accurate readings within 1/500 of a turn.  
Bourns® Model CT-26 recessed mounting digital turns-counting dial,  
counterpart to the Bourns Model CT-23, provides a lower panel  
profile. The design simplifies installation requiring only one panel  
hole. The CT-26 maintains the same high level of symmetry,  
legibility and accuracy of its counterpart.  
CT-23 MOUNTING INSTRUCTIONS  
CT-26 MOUNTING INSTRUCTIONS  
1. Drill or punch panel. See suggested hole pattern below.  
2. Insert potentiometer in panel.  
1. Drill or punch panel. See suggested hole pattern below.  
2. Insert turns-counting dial in panel cutout and secure with  
mounting nut.  
3. Mount potentiometer in panel with nut and lockwasher supplied  
with the potentiometer.  
3. Secure locator plate to potentiometer bushing using two hex  
nuts.  
4. Turn the potentiometer shaft counterclockwise to obtain minimum  
resistance or voltage ratio (not necessarily at the end of travel).  
5. Loosen set screw in knob with allen wrench. Set the dial readout  
to “000.”  
6. Slip the dial carefully over the potentiometer shaft. Tighten the  
set screw without causing movement of the dial readout or  
potentiometer shaft.  
4. Turn the potentiometer shaft counterclockwise to obtain minimum  
resistance or voltage ratio (not necessarily at the end of travel).  
5. Loosen set screw in turns-counting dial with allen wrench. Set  
the dial readout to “000.”  
6. Slip the potentiometer shaft into the turns-counting dial, insuring  
that the notch in the locator plate is over the pin at the rear of the  
dial. Tighten the set screw without causing movement of the dial  
readout or potentiometer shaft.  
For mounting, the maximum recommended panel thickness is  
1/8 " (3.1 mm).  
MM  
(IN.)  
DIMENSIONS:  
Dimensional Drawings  
How to Order  
Part  
Number  
Accepts Shaft  
Diameter  
Finish  
CT-23-6A 6.35 mm (.250)  
CT-23-6M 6 mm (.236)  
CT-26-6A 6.35 mm (.250)  
CT-26-6M 6 mm (.236)  
Black  
Knurl  
with Satin  
Chrome  
Face  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  
REV. 04/06  

CT-26-6A 替代型号

型号 品牌 替代类型 描述 数据表
H-516-6A BOURNS

功能相似

DIAL COUNTING 0-15 TURNS

与CT-26-6A相关器件

型号 品牌 获取价格 描述 数据表
CT266DZB CYPRESS

获取价格

Voltage Controlled Oscillator, 70MHz Max
CT-26-6M BOURNS

获取价格

Turns-Counting Dial
CT2674A ETC

获取价格

OPROBE X1/X10/R 100MHZ HIPRO 1.2
CT2675A ETC

获取价格

OPROBE X1/X10/R 200MHZ HIPRO 1.2
CT2676A ETC

获取价格

OPROBE X10 100MHZ HIPRO 1.2M
CT2676ARA ETC

获取价格

OPROBE X10 100MHZ W/RO HIPRO 1.2
CT2678 ETC

获取价格

OPROBE X1 15MHZ HIPRO 1.2M
CT2700 ETC

获取价格

TEST LEAD BANANA TO PROBE 39.4"
CT2701A ETC

获取价格

COAX ADAPTER KIT NPLT ZIPPER POU
CT2702A ETC

获取价格

GEN PUR GRADE BNC & N TYPE ADAPT