Catalog 1308242
Issued 3-03
P&B
CS series
Solid State Hybrid Voltage Sensor
• Close differential
• Choice of two types
– Fixed pick-up and knob adjustable drop-out
– Knob adjustable pick-up and drop-out
• Internal 2 Form C (DPDT) output relay
File E22575
Fixed Pick-up and
Adjustable Drop-out
Adjustable Pick-up
and Drop-out
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Engineering Data
Sensing Modes
Pow er Requirem ent: Typically less than 3VA or 3W.
Duty Cycle: Continuous.
Repeatability: ±1% , max.
The CS can be used as an over or undervoltage sensor, depending upon
whether the load is connected to the normally closed (NC) or normally open
(NO) contacts of the sensor’s output relay.
Response Tim e: 10-25 ms, typ.
Internal Relay Contact Arrangem ent: 2 Form C (DPDT).
Internal Relay Contact Rating: 10A @ 28VDC , res., or 120VAC, 80% p.f.
Reverse Polarity Protection: On DC types.
Tem perature Range: -10°C to +55°C.
Tem perature Coefficient: 0.2% /°C, max.
Enclosure: Plastic dust cover.
Overvoltage sensor – The NC contacts are used. The relay remains de-
energized until an overvoltage is sensed.
Undervoltage sensor – The NO contacts are used. The relay remains en-
ergized until the voltage decreases to the preset level, where the sensor
de-energizes the relay.
Mounting: 8-pin octal style plug. Fits either 27E122 or 27E891 (snap-on)
screw terminal sockets.
Weight: 8 oz. (227g) approximately.
Adjustable Voltage Sensor Operation
Ordering Inform ation –
Distributors are m ore likely to stock boldface item s.
Note 1 – As voltage increases, the
relay will pick-up at its selected
point and remain energized while
voltage is maintained at that level or
higher.
RELAY
Fixed Pick-Up and Adjustable Drop-Out
ENERGIZED
Part Num ber
Pick-Up
(Volts)
Drop-Out Range
(Volts)
Maxim um
Voltage
CSJ -38-71010
CSL-38-31010
105
22
90-103
16-21
140VAC (50/60 Hz.)
32VDC
Note 2 – As voltage decreases, af-
ter pick-up, the relay will drop-out at
its selected point.
HYSTERISIS
Adjustable Pick-Up and Adjustable Drop-Out
2 VOLTS
Part Num ber
Pick-Up Range Drop-Out Range*
Maxim um
Voltage
(Volts)
(Volts)
Note 3 – Minimum hysterisis, the
RELAY
DE-ENERGIZED
CSJ -38-70010
CSL-38-30010
CSL-38-40010
CSL-38-60010
92-140
20-30
40-58
90-138
18-28
38-56
150VAC (50/60 Hz.)
32VDC
voltage differential between pick-up
and drop-out, is typically 2% of
pick-up.
60VDC
150VDC
92-140
90-138
* Actual maximum drop-out voltage is the selected pick-up voltage less the hysterisis
voltage.
NOTE 1
NOTE 2
Wiring Diagram s – Bottom View s
(pins num bered clockw ise from keyw ay)
Outline Dim ensions
1.781 MAX.
.600 MAX.
(15.24)
2.937 MAX.
(76.60)
(42.24)
.875
.560
(14.22)
(22.23)
-
+
1.187
(30.15)
AC
INPUT
DC
INPUT
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com