DIN Rail Mount
DataSheet
CMR60 Series
• Ratings from 35A to 65A @ 660 VAC
• 45mm (width) package
• SCR output for heavy industrial loads
• LED input status indicator
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage
4-32 VDC
35 A
45A
55A
65A
CMRD6035
CMRA6035
CMRA6035E
CMRD6045
CMRA6045
CMRA6045E
CMRD6055
CMRA6055
CMRA6055E
CMRD6065
CMRA6065
CMRA6065E
90-140 VAC
18-36 VAC
AVAILABLE OPTIONS
Operational Current
35: 35 Amps
45: 45 Amps
55: 55 Amps
65: 65 Amps
Control Voltage
D: 4-32 VDC
A: 90-140 VAC
Overvoltage Protection
Blank: No Included
P: Included
Series
A
60
35
E
P
-10
CMR
Input Range
Blank: Standard Input
E: 18-36 VAC
Switching Mode
Blank: Zero Voltage Turn-on
-10: Random Turn-On
Operating Voltage
60: 48-660 VAC
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS (1)
Description
35A
48-660
1200
1.0
500
45A
48-660
1200
1.0
500
45
55A
48-660
1200
1.0
500
55
65A
48-660
1200
1.0
500
65
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] (2)
Maximum Load Current [Arms]
35
0.15
239/250
1.7
1.02
285/259
0.5
0.15
597/625
1.7
0.63
1779/1621
0.5
0.25
954/1000
1.7
0.31
4555/4150
0.5
0.25
1145/1200
1.7
0.28
4555/4150
0.5
Minimum Load Current [Arms]
Maximum Surge Current (50/60Hz, 1 Cycle) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec]
Minimum Power Factor (with Maximum Load)
FDE-07-01 REV. A
Do not forget to visit us at: www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.