MIXERS
TRIPLE-BALANCED
IMPROVED DYNAMIC RANGE
LO = +10 dBm
133
159
SURFACE MOUNT
FREQUENCY RANGE
(MHz)
CONVERSION
LOSS (dB)
LO-RF ISOLATION
(dB)
LO-IF ISOLATION
(dB)
PIN
OUT
MODEL
PACKAGE
XMB
FULL
BAND
LB
MB
UB
LB
MB
UB
RF/LO
IF
TYP/MAX
TYP/MAX
TYP/MIN
TYP/MIN
TYP/MIN
TYP/MIN TYP/MIN
TYP/MIN
1 - 2500
5 - 1000
25 - 1800
50 - 2500
800 - 3550ꢀ
1 - 2000
5 - 1000
25 - 1000
50 - 880
6.5/8.5 8.0/9.5
6.5/8 7.5/9.5
7.5/8.5 8/9
7/8.5 8/9.2
10/11.8
45/35
35/20
50/30
44/35
--/--
35/25
40/30
45/25
--/--
28/20
30/23
35/20
40/30
28/20
40/30
30/20
30/15
38/28
--/--
26/20
30/20
25/15
--/--
22/16
25/20
23/15
25/20
23/15
133
159
133
133
133
2
1
2
2
2
SMD-C8
SLD-K5
SMD-C5
SMD-C7
SMD-C9**
800 - 2500 --/--
--/--
--/--
105
103
102
THROUGH HOLE (RELAY)
FREQUENCY RANGE
(MHz)
CONVERSION
LOSS (dB)
LO-RF ISOLATION
(dB)
LO-IF ISOLATION
(dB)
PIN
OUT
PACKAGE
MODEL
XMB
FULL
BAND
LB
MB
UB
LB
MB
UB
RF/LO
IF
TYP/MAX
TYP/MAX
TYP/MIN
TYP/MIN
TYP/MIN
TYP/MIN TYP/MIN
TYP/MIN
0.05 - 200
10 - 1000
0.05 - 1500 0.05 - 500
0.05 - 2000 0.05 - 500
10 - 2500
500 - 3700
0.05 - 200
5 - 500
5.5/6.5
6/7.5
6/7.5
6/8
6.5/7
7/8
7/9
7/9
7.5/8.5
9.5/11.5
45/30
50/40
25/20
25/20
55/35
45/25
50/45
40/30
35/25
40/30
45/30
45/25
45/40
30/20
30/20
30/20
35/25
45/25
35/25 40/35
40/25 30/18
25/20 35/25
25/20 40/30
35/20 35/20
40/20 40/20
35/30
25/15
25/15
25/15
27/20
40/20
102
102
102
102
103
103
3
4
3
3
3
3
CLP-206
CLP-2P4
CLP-2H5
CLP-2B6
CLP-205
CLP-210
10 - 1000
500 - 1000 --/--
7/8
10 - 2000
10 - 2500
10 - 3000
500 - 3700
10 - 1000
10 - 1000
10 - 800
6/8
7/8
6.3/8
--/--
6.5/8
32/25
55/35
35/25
45/25
35/25
45/30
35/25
45/25
35/25
35/25
35/25
45/25
33/20 30/20
35/20 30/20
30/20 30/20
40/20 40/20
30/20
27/20
30/20
40/20
105
105
105
105
5
6
5
6
CLP-3E6
CLP-305
CLP-3B8
CLP-310
7.5/8.5
6.5/8.5
9.5/11.5
500 - 1000
NOTES:
PIN-OUT TABLE
1. 1dB Compression Point = +5 dBm (Typ)
2. IP3 (Input) = +18 dBm (Typ)
RF
LO
IF
GND
CASE GND
NO CONN.
3. As IF frequency decrease below LF towards DC, conversion loss increases
up to 8 dB higher than maximum.
4. Maximum Input Power without damage = 250 mW ave. cw
ꢀ LO Frequency is specified from 600 to 2595 MHz
** UB identifies the full bandwidth specification
#1
#2
#3
#4
#5
#6
4
1
1
8
4
1
1
2
8
1
1
4
5
3
3
3
2
2
2,3,6
--
--
--
4
4
--
--
4,5,6
2,5,6,7
2,5,6,7
3
--
2,5,6,7
2,5,6,7
3
3
3
ALL MODELS
MODEL SMD-C7
GND = Ground externally
For pin location and package outline drawings, see back pages.
*Connect pins together externally.
XMB= 2LF to HF/2
FULL BAND = LF to HF
LB= LF to 10LF
XMB = 750 - 1000 MHz
LB = 750 - 1200 MHz
UB =1200 - 2500 MHz
MB = 10LF to HF/2
UB= HF/2 to HF
201 McLean Boulevard • Paterson, New Jersey 07504 •Tel: (973) 881-8800 • Fax: (973) 881-8361
E-Mail: sales@synergymwave.com • World Wide Web: http://www.synergymwave.com
[ 76 ]