Features
Applications
■ Select models are compliant with
AEC-Q200 Rev-C Stress Test Qualification
for Passive Components in Automotive
Applications (see chart below)
■ HDMI 1.4
■ Digital Visual Interface (DVI)
■ USB 3.0 / USB OTG
■ Memory protection
■ SIM card ports
■ RoHS compliant*
■ ESD protection >25 kV
■ Low capacitance <0.5 pF
■ Low leakage current <50 nA
■ Automotive
ChipGuard® MLC Series - ESD Protectors
General Information
AEC Approved Models
®
The ChipGuard MLC Series has been specifically designed to protect sensitive electronic
components from electrostatic discharge damage. The MLC family has been designed to
protect equipment to IEC61000-4-2, Level 4 (±± kV Contact ꢀ ±15 kV Air Discharge) ESD
specifications targeted for high speed USB 3.0ꢀUSB OTG, HDMI 1.4, DVI or IEEE1394
applications.
Model
AEC-Q200
✓ Yes
✓ Yes
✓ Yes
✓ Yes
CG0603MLC-05E
CG0603MLC-05LE
CG0603MLC-05LEA
CG0603MLC-12E
CG0603MLC12LE
CG0603MLC-12LEA
Device Symbol
®
The ChipGuard MLC Series has been
manufactured to provide low 0.5 pF
✓ Yes
✓ Yes
capacitance and leakage currents less than
50 nA with excellent clamp qualities, making
the family almost transparent under normal
working conditions.
V
Electrical Characteristics @ 25 °C (unless otherwise noted)
CG0402MLC-
Parameter
Symbol
Unit
3.3LG
05LG
12LG
24LG
3.3LGA
05LGA
12LGA
24LGA
24
Typical Continuous Operating Voltage
Typical Clamping Voltage (Note 1)
Maximum Capacitance @ 1 VRMS 1 MHz
Maximum Leakage Current @ Max. VDC
Typical Trigger Voltage (Note 2)
V
3.3
5
12
24
3.3
5
12
V
V
DC
V
25
C
O
L
T
T
C
I
V
R
0.5
5
250
1
pF
nA
V
Maximum Response Time
ns
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
kV
kV
kV
˚C
˚C
±±
±15 (Note 3)
±25
Min. Air Discharge
Operating Temperature
Storage Temperature
T
T
-40 to +±5
-40 to +125
OPR
-55 to +150
STG
CG0603MLC-
Parameter
Symbol
Unit
3.3LEA
3.3LE
3.3
05E
5
05LE
5
12E
12
30
12LE
24LE
05LEA 12LEA 24LEA
12 24
Typical Continuous Operating Voltage
Typical Clamping Voltage (Note 1)
Maximum Capacitance @ 1 VRMS 1 MHz
Maximum Leakage Current @ Max. VDC
Typical Trigger Voltage (Note 2)
V
12
24
3.3
5
V
V
DC
V
25
20
25
25
C
O
L
C
0.5
pF
nA
V
I
5
250
50
150
5
250
50
150
5
V
R
250
T
T
Maximum Response Time
1
ns
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
kV
kV
kV
˚C
˚C
±±
±15 (Note 3)
±25
Min. Air Discharge
Operating Temperature
Storage Temperature
T
T
-40 to +±5
-40 to +125
OPR
-55 to +150
STG
Notes: 1. Per IEC 61000-4-2, Level 4 ± kV Contact Discharge. Measurement 30 ns after initiation of pulse.
2. Per IEC 61000-4-2, Level 4 ± kV Contact Discharge. Measurement at maximum pulse voltage.
3. IEC 61000-4-2 ESD Performance for CG0603MLC-05E and CG0603MLC-12E devices will meet minimum 100 reps.
Some shifting in characteristics may occur when tested over several hundred ESD pulses. All other part numbers listed will meet
IEC 61000-4-2 ESD Performance with minimum 1000 reps without degradation in performance.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.