Ordering information
Power module type
CD
S
600 48
12
CDS60048
1
2
3
4
5
1Series name
2Single output
3Output wattage
4Input voltage
48:DC36 - 76V
5Output voltage
R
MODEL
CDS6004812
CDS6004828
700
MAX OUTPUT WATTAGE[W]
DC OUTPUT
700
12.5V 56A
28V 25A
SPECIFICATIONS
MODEL
CDS6004812
DC36 - 76
17typ
CDS6004828
VOLTAGE[V]
1
*
INPUT
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
17typ
(
,
)
,
(
,
)
(
,
),
(
,
)
89typ DCIN 48V Io=100% 91typ DCIN 48V Io=50% 89typ DCIN 48V Io=100% 90typ DCIN 48V Io=50%
12.5
56
28
25
LINE REGULATION[mV] 40max
LOAD REGULATION[mV] 100max
95max
190max
120max
160max
150max
180max
280max
480max
90max
2
*
2
*
2
*
2
*
0
to +85
120max
160max
150max
180max
C
RIPPLE[mVp-p]
-20 - 0
C
0
to +85
C
OUTPUT
RIPPLE NOISE[mVp-p]
-20 - 0
C
0 to +65 120max
C
TEMPERATURE REGULATION[mV]
-20 to +85 200max
C
3
*
DRIFT[mV]
40max
(
,
)
START-UP TIME[ms]
200max DCIN 48V Io=100%
(
),
OUTPUT VOLTAGE ADJUSTMENT RANGE Fixed TRM pin open 80 - 110% adjustable by external VR or external voltage
OUTPUT VOLTAGE SETTING[V] 12.00 - 13.00
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
26.88 - 29.12
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V] 14.35 - 17.50
32.20 - 39.20
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
Provided
(
)
Provided On both side of input and output
,
,
(
)
)
AC500V 1minute Cutoff current = 10mA DC500V 50M min 20 15
W
t
C
,
,
(
AC500V 1minute Cutoff current = 10mA DC500V 50M min 20 15
W
t
C
ISOLATION
, , (
AC500V 1minute Cutoff current = 100mA DC500V 50M min 20 15
W t
)
)
OUTPUT-FG
C
,
, , (
AC100V 1minute Cutoff current = 100mA DC100V 10M min 20 15
W t
OUTPUT-RC2 RC3
C
,
(
),
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -20 to +85
On aluminum base plate 20 - 95%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
C
,
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -40 to +85
20 - 95%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
)
,
,
VIBRATION
10 - 55Hz 49.0m/s 5G 3minutes period 60minutes each along X Y and Z axis
(
),
,
,
IMPACT
196.1m/s2 20G 11ms once each X Y and Z axis
CDS SAFETY
, ,
UL60950 C-UL EN60950
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
(
)
H D / 200g max
X
61 12.7 116.8mm W
X
X
X
OTHERS
(
)
Conduction cooling e.g. heat radiation from the aluminum base plate to the attached heat sink
*1 At rated input(DC48V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board with recommended capacitor Co & the film capacitor 0.1mF.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101).
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
G-76