’HC4051, ’HCT4051, ’HC4052, CD74HCT4052, ’HC4053, CD74HCT4053
DC Electrical Specifications (Continued)
TEST CONDITIONS
AMBIENT TEMPERATURE, T
A
o
o
o
o
o
25 C
-40 C - 85 C -55 C - 125 C
V
V
(V)
V
(V)
V
CC
(V)
IS
(V)
I
EE
PARAMETER
HCT TYPES
High Level Input Voltage,
MIN
TYP
MAX
MIN
MAX
MIN
MAX UNITS
4.5 to
5.5
2
-
-
-
-
2
-
-
2
-
-
V
V
V
IH
Low Level Input Voltage,
4.5 to
5.5
0.8
0.8
0.8
V
IL
On Resistance, r
V
V
or V
V or
IL
0
-
4.5
-
-
-
-
-
-
-
-
-
-
70
-
160
-
-
-
-
-
-
-
-
-
200
-
-
-
-
-
-
-
-
-
240
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
ON
= 1mA, (Figure 15)
CC
CC
EE
I
V
O
IH
-
-
-
-4.5
0
4.5
4.5
-
40
90
-
120
150
180
to V
180
225
270
EE
-
-
-
-
-4.5
0
4.5
4.5
-
45
10
-
130
162
195
Maximum On Resistance
Between any Two
Channels, ∆r
ON
-
-
-
-
-
-
-
-
-
-
-4.5
4.5
5
Switch On/Off Leakage
Current, I
For Switch Off:
V
V
or
IL
When V = V
,
IZ
IS CC
IH
V
= V
;
OS
EE
1 and 2 Channels
4053
0
-5
0
6
5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
±0.1
±0.1
±0.1
±0.2
±0.2
±0.4
±0.1
-
-
-
-
-
-
-
±1
±1
±1
±2
±2
±4
±1
-
-
-
-
-
-
-
±1
±1
±1
±2
±2
±4
±1
µA
µA
µA
µA
µA
µA
µA
When V = V
,
EE
IS
= V
V
OS
CC
For Switch On:
All Applicable
Combinations of
V
4 Channels
4052
6
-5
0
5
and V
IS
OS
8 Channels
4051
Voltage Levels
6
-5
-
5
Control Input Leakage
-
(Note 4)
5.5
Current, I
IL
Quiescent Device
Current, I
When V = V
IS
,
V
or
0
5.5
5.5
-
-
-
-
-
8
-
-
-
80
-
-
-
160
320
490
µA
µA
µA
EE
CC
GND
V
= V
CC
OS
CC
I
= 0
O
When V = V
,
-4.5
16
160
450
IS
= V
CC
V
OS
EE
Additional Quiescent
Device Current
Per Input Pin: 1 Unit
Load
∆ICC
(Note 5)
V
-
4.5 to
5.5
100
360
CC
2.1
NOTES:
4. Any voltage between V
and GND.
CC
5. For dual supply systems theoretical worst case (V = 2.4V, V
= 5.5V) specification is 1.8mA.
I
CC
HCT Input Loading Table
UNIT LOADS
TYPE
4051, 4053
INPUT
All
(NOTE)
0.5
4052
All
0.4
NOTE: Unit load is ∆I
e.g., 360mA max. at 25 C.
limit specified in DC Specifications table,
CC
o
8