CAP200 Series Contactor With 1 Form A (SPST-NO)
Contacts Rated up to 500 Amps, 12-900VDC
Product Facts
ꢀ Designed to be the smallest,
lightest weight, lowest cost
sealed contactor in the industry
with its current rating.
ꢀ Built-in coil economizer – only
1.7W hold power @ 12VDC and
it limits back EMF to 0V.
(models requiring extenal
economizer also available).
ꢀ Optional auxiliary contact for
easy monitoring of power
contact postion.
ꢀ Hermetically sealed –
intrinsically safe, operates in
explosive/harsh environments
with no oxidation or
contamination of coils or
contacts, including long periods
of non-operation.
ꢀ Versatile coil and power
connections.
ꢀ UL Recognized for the U.S. and
Canada (File E208033).
ꢀ CE marked for EC applications.
ꢀ AIAG QS9000 designed, built
and approved
For factory-direct application assistance, dial
800-253-4560, ext. 2053, or 805-220-2053.
Performance Data
Parameter
Contact Arrangement, power contacts
Rated Operating Voltage
Units Value for CAP200 Series
1 Form A (SPST-NO)
VDC 12 - 900
Coil Operating Voltage (valid over temperature range)
Voltage (will operate)
Voltage (Max.)
9-36VDC
36VDC
9VDC
32-95VDC 48-95VDC
95VDC
32VDC
22VDC
18VDC
1.3A
95VDC
48VDC
34VDC
27VDC
0.7A
Continuous (Carry) Current, Typical
A
500 @ 85°C, 400 mcm conductors
Pickup (close) Voltage Max.
Hold Voltage (Min.)
Consult Factory for required conductors for higher currents
7.5VDC
6VDC
Make/Break Current at Various Voltages 1
A
A
See next page
2,000, 1 cycle 3
/
Dropout (open) Voltage (Min.)
Inrush Current (Max.)
Holding Current (Avg.)
Inrush Time (Max.)
Break Current at 320VDC 1
/
/
3.8A
Contact Resistance, Typ. (@200A)
Load Life
Mechanical Life
mohms 0.2
Cycles See next page
Cycles 1 million
0.13A@12V, 0.07A@24V 0.03A@48V 0.02A@72V
130ms
130ms
130ms
Contact Arrangement, auxiliary contacts
1 Form A (SPST-NO)
Aux. Contact Current, Max.
Aux. Contact Current, Min.
A
mA
2A @ 30VDC / 3A @ 125VAC
100mA @ 8V
Aux. Contact Resistance, Max.
Dielectric Withstanding Voltage
Insulation Resistance @ 500VDC
Shock, 11ms 1/2 sine, peak, operating
Vibration, sine, 80-2000Hz., peak
Operating Temperature
ohms 0.417@ 30VDC / .150 @ 125VAC
Vrms 2,200 @ sea level
Part Numbering System
Typical Part Number
Series:
CAP200 = 500 Amp, 12-900VDC Contactor
CAP200
A
A
A
N
A
megohms 100 2
/
G
G
20
20
Contact Form:
A = Normally Open
°C
-40 to +85
H = Normally Open with Aux. Contacts
Weight, Nominal
lb.(kg) .95 (.43)
Coil Voltage:
A = 9-36VDC (1 = requires external coil economizer)
D = 32-95VDC (2 = requires external coil economizer)
J = 48-95VDC (3 = requires external coil economizer)
1/ Main power contacts
2/ 50 at end of life
3/ Does not meet dielectric & IR after test, 1700 amp for unit with Aux. Contacts
4/ Use with AMP LOUVERTAC 5-192013-9. Consult factory for threaded mount socket.
Coil Wire Length:
A = 15.3 in (390 mm)
B = 6.0 in (152 mm)
Coil Terminal Connector:
N = None
E = 9-pin subminiature “D” plug mounted on contactor housing
F = 9-pin subminiature “D” plug mounted on 15.3 in (390 mm) flying leads.
X = Special configuration (consult factory)
© 2004 by Tyco Electronics Corporation. All Rights Reserved.
KILOVAC, AMP, LOUVERTAC and TYCO are trademarks.
Other products and company names mentioned herein may be trademarks of their
respective owners.
Mounting & Power Terminals:
/
A = Bottom Mount & Male 10mm x 8 Terminals
C = Plug-in Terminals4
1
Catalog 1654770
Revised 6-04
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
USA: 1-800-522-6752
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
reference purposes only.
Specifications subject
to change.
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
www.tycoelectronics.com
UK: 44-141-810-8967