7
C-Series Circuit Breaker - Handle UL489 & UL489A Listed / Parallel Pole – Ordering Scheme
C A 2 P 0 D4 820 3 2 1 M T
8
9
10
Mounting
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
5
8 TERMINAL
1 SERIES
3
6
A
1/4-20 threaded Stud
M6 threaded Stud
Plug-In Stud
C
3
2 ACTUATOR
A
S
T
Handle, one per pole
2
1
9 ACTUATOR COLOR
Mid-Trip Handle, one per pole
1
LEGEND
ON-OFF
Mid-Trip, one per pole & Alarm Switch
Dual
Legend Color
Black
White
Black
Red
Green
Blue
Yellow
Gray
Orange
B
D
G
J
1
2
3
4
5
6
7
8
4
3 POLES
White
1
2
3
One
White
Two
White
Three
L
White
N
Q
S
Black
Black
Black
4 CIRCUIT
P
Series Trip (parallel pole)
10 MOUNTING
5 AUXILIARY / ALARM SWITCH
Threaded Insert
0
2
3
4
without Aux Switch
6
7
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C
Term. (Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
1
2
6-32 x 0.195 inches
ISO M3 x 5mm
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
8
9
11 MAXIMUM APPLICATION RATING
80 DC
5
S.P.S.T., N.O., 0.110 Q.C
Term. (Gold Contacts)
M
6
12 AGENCY APPROVAL
6 FREQUENCY & DELAY
D1 DC Ultra Short
D2 DC Short
A
G
J
Without Approval
UL489 Listed
UL489A Listed, TUV Certified
UL489A Listed, VDE Certified
UL489A Listed
D4 DC Medium
D6 DC Long
K
T
7
UL489A Listed, TUV Certified
4
7 CURRENT RATING (AMPERES)
CODE AMPERES
Notes:
810 100.00
811 110.00
812 120.00
912 125.00
813 130.00
814 140.00
815 150.00
816 160.00
817 170.00
917 175.00
818 180.00
819 190.00
820 200.00
922 225.00
825 250.00
1
Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is
specified. When Actuator Code T is specified, handle moves to Mid Position and
Alarm Switch actuates only upon electrical trip of C/B. Code T is only available with
Circuit Code N.
2
3
Standard Handle colors are White, Black, Red & Yellow.
Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line
and Load Terminals. For Terminal Code A, Line and Load Terminals must be
connected to a copper bus bar having a minimum cross-section of 0.078 square
inches. Terminal Code A is not available on the single pole unit.
Ratings for 101 to 125 amps are available in 1-pole.
4
Ratings from 110 to 200 amps are available in 2-pole.
For ratings from 225-300 amps, specify 3-pole.
1 pole only available with terminal codes 3 and 6.
Agency codes K and 7 are not available with 1 pole.
5
6
Agency code J is only available with 1 pole.
Agency code G is only available in 2 and 3 pole.
Circuit P, ratings 101-150 amps (2 pole) and ratings 151-250 amps (3 pole).
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com