BU52001GUL,BU52011HFV,BU52021HFV,BU52015GUL,BU52025G,BU52053NVX,
BU52054GWZ,BU52055GWZ,BU52056NVX,BU52061NVX,BD7411G
Technical Note
BU52015GUL (Unless otherwise specified, VDD=1.80V, Ta=25℃)
Limits
Parameter
Symbol
Unit
V
Conditions
Min.
1.65
Typ.
Max.
3.30
Power Supply Voltage
VDD
1.80
BopS
BopN
BrpS
-
3.0
-3.0
2.1
-2.1
0.9
0.9
5.0
Operate Point
mT
mT
mT
ms
V
-5.0
-
0.6
-
Release Point
BrpN
-
-
-
-0.6
BhysS
BhysN
-
-
Hysteresis
Period
Tp
-
50
-
100
19
19
※
OUT1: BrpN<B<BrpS
OUT2: B<BopN, BopS<B
IOUT = -0.5mA
Output High Voltage
Output Low Voltage
Supply Current 1
Supply Current During Startup Time 1
VOH
VDD-0.2
-
0.2
8
※
OUT1: B<BopN, BopS<B
OUT2: BrpN<B<BrpS
IOUT = +0.5mA
VOL
-
-
-
-
-
-
-
-
V
IDD1(AVG)
5
µA VDD=1.8V, Average
VDD=1.8V,
mA
IDD1(EN)
2.8
1.8
8
-
During Startup Time Value
VDD=1.8V,
Supply Current During Standby Time 1 IDD1(DIS)
-
µA
During Standby Time Value
Supply Current 2
IDD2(AVG)
12
-
µA VDD=2.7V, Average
VDD=2.7V,
Supply Current During Startup Time 2
IDD2(EN)
4.5
4.0
mA
µA
During Startup Time Value
VDD=2.7V,
Supply Current During Standby Time 2 IDD2(DIS)
-
During Standby Time Value
※19 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
www.rohm.com
2011.12 - Rev.G
5/31