BR6G SERIES
GLASS PASSIVATED
BRIDGE RECTIFIERS
REVERSE VOLTAGE
FORWARD CURRENT
- 50 to 1000Volts
- 6.0 Amperes
BR6
FEATURES
● Surge overload rating -150 amperes peak
.276(7.0)
.236(6.0)
● Low forward voltage drop
● Small size; simple installation
● Sliver plated copper leads
.750
(19.0)
MIN
● Mounting position: Any
.042(1.07)
DIA.
.038(0.97)
HOLE FOR
NO.6 SCREW
.620(15.7)
.580(14.7)
.445(11.3)
.405(10.3)
.620(15.7)
.580(14.7)
.445(11.3)
.405(10.3)
Polarity shown on side of case, Positive lead by beveled corner.
Dimensions in inches and (milimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
SYMBOL BR6005G BR601G BR602G BR604G BR606G BR608G BR610G
UNIT
CHARACTERISTICS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Bridge Input Voltage
VRRM
VRMS
50
35
100
70
200
140
400
280
600
420
800
560
1000
700
V
V
Maximum Average Forward
Rectified Output Current at
Peak Forward Surage Current
8.3ms Single Half Sine-Wave
Super Imposed on Rated Load
Tc=100℃ (Note1)
TA=50℃ (Note2)
6.0
3.0
I(AV)
A
A
V
IFSM
150
Maximum Forward Voltage Drop
VF
IR
1.1
Per Bridge Element at 3.0A Peak
10.0
1.0
Maximum Reverse Current at Rated TA=25℃
μA
DC Blocking Voltage Per Element
Operating Temperature Range
TA=100℃
mA
-55 to +150
-55 to +150
TJ
℃
℃
Storage Temperature Range
TSTG
Notes:1.Unit mounted on metal chassis
2. Unit mounted on P.C. board
~
~